I am changing the fundamental frequency and the maximum harmonic value and the dc offset is coming different every time. how do I set the accurate parameters?
Do you make AC or Transient analysis. Transient is only meaningful for a starting portion of your waveform(e.g., from 0 to pi/2 of a sine wave
The DC component of a transient depends on how long it is and how long the data is. It is the mean value of all the data.
A transient response only lasts for a short while. A sine wave goes on for ever, which one are you analysing?
Dear Shivansh Awasthi ,
Please the display the waveform of the time domain. and then display the the FFT which you get. In this way one can put a specific reply.
The DC component is the average value of the waveform.
It will be seen as a discrete value at the zero frequency.
Best wishes
do we need to change the GaN material mobility in tcad with the hall mobility in the experimental paper? and do we need to match the sheet charge density too? Is this sheet charge density...
19 March 2024 7,604 0 View
The mobility model that I am using is DopingDependence model and Transferredelectrton2 for high field degradation of mobility by intervalley scattering. This should reduce the current but it is...
13 March 2024 1,781 0 View
Solution is not converging after gate voltage reaches 1.34 V and Id is 200mA
13 March 2023 2,765 1 View
min step=1e-3 max step=0.01 minstep=1e-5 increment =1.55 , models is hydrodynamic, math i have tried with default and also blocked and pardiso
01 March 2023 8,320 2 View
solve qfactor=0.0001 solve qfactor=0.0005 solve qfactor=0.004 solve qfactor=0.02 solve qfactor=0.1 solve qfactor=1.0 trying out all the combinations but still convergence issues
10 December 2020 9,796 2 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View
What is the prepared reference material that can be used in the ICPE-9820 Shimadzu Japan instrument, which employs inductively coupled plasma optical emission spectrometry (ICP-OES) to measure...
06 August 2024 1,896 1 View
I am interested to know the behavior of dyes toward light. Specifically, Blue dyes re-emit the spectrum, especially from the green zone (known as principal in LED lamps, and blue dyes are known...
05 August 2024 3,290 1 View
Is it possible to conduct a molecular dynamics simulation to see the effects of a specific carbohydrate on the structure of lipids (e.g., micelle structure)? I am a beginner in this field and plan...
03 August 2024 3,371 3 View
I am using a windows system, what software I should use for hydration shell analysis with molecular dynamics?
02 August 2024 3,143 4 View
I am trying to adapt adherent CHO-K1 cells in F12K+10%FBS to suspension culture in only F12K, but in vain. I have followed Mirus bio as well as Thermo protocols, please suggest any alternative....
31 July 2024 3,756 0 View
Can we patent a process flow diagram developed using a process simulator but no actual cases is carried out? For example consider a process for certain product manufacture where a new process flow...
31 July 2024 781 1 View
Hello. Thanks for your consideration to see my question. Recently, I conducted XPS anaylsis of g-CN that is prepared from thermal polycondensation of DCDA, so-called conventional bulk-g-CN,...
30 July 2024 9,824 2 View
I am beginning to use OG+ in my district and noticed during training there are a lot of materials and routines, which may be overwhelming for my students, especially those on the autism spectrum....
30 July 2024 5,695 0 View
I went for Plackett Burman Design for selecting the optimization factors of growth conditions for pesticide degradation. I started with 7 parameters. But, after the experiments and analysis, only...
29 July 2024 5,015 1 View