Could someone explain this Arrhenius plot? how can i understand that the positive slope indicates ohmic contact and negative indicates schottky contact?
Congratulations if this is the data You measured! Very beautiful result!
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
I want to analyses the proportion of swimming sperm of three species of fish in two salinities. To analyse the proportion of swimming sperm in a Generalized Linear Model, I would use a Binary...
03 March 2021 2,297 3 View
03 March 2021 8,272 1 View
Hi. Please tell me what guidelines should i need to follow for questionaries' type research work in India. It is not hospital based work, we are conduction basic institutional based qualitative...
03 March 2021 2,037 3 View
Hi, I implemented a code to gabor filter cifar10 data but the images after being filtered and stacked are not clear like the original images. I think the problem is in the way I am using the...
03 March 2021 6,317 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
03 March 2021 5,360 2 View
The term miscibility refers to the single-phase state in thermodynamics. I do not mean the compatibility of different components. To determine the miscibility I know several techniques such as...
03 March 2021 4,107 4 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
02 March 2021 5,204 3 View
The temperature dependence of the resistance (R-T) measurement of High Resistance State (HRS) gives the thermal activation energy (Ea) using Arrhenius equation as given below R=R0exp(Ea/KBT) So,...
16 September 2020 3,008 6 View
We use ECOPIA Hall Effect measurement system (Model no. HMS-5300 + AMP55T magnet) in our lab. I am trying to determine the carrier concentration and mobility of PbS thin films. I have made...
06 February 2020 6,944 4 View
01 February 2020 5,024 4 View
Greetings. I am having trouble achieving ohmic contacts between Aluminium and Germanium that work at low temperatures. My contacts behave ohmically at room temperature, with a relatively high...
09 January 2020 629 4 View
31 December 2019 4,713 4 View
Hello, question is above. Thanks.
09 October 2019 6,250 1 View
What should be the ohmic contacts to be used for SCLC measurements on TiO2 ? Is it possible in a lateral configuration ? What other characterizations can be done to extract trap density in metal...
31 December 2018 4,571 5 View
Hi, I made a Metal-GaN structure in Silvaco TCAD. GaN was doped to a level of 1E17. Also I modeled with and without heavy doping of the near-contact region of the semiconductor for...
11 December 2018 4,181 0 View
I am working on III-V junction solar cell based water splitting .in my case i don't want to use noble metals as a back electrode(ohmic contact ) .can any one suggest me best earth abundant...
28 October 2018 3,728 3 View
09 October 2018 8,838 4 View