Hi I want to program C1000 for touchdown PCR protocol (pl see enclosed file)
If someone can help me how to enter it in C1000 machine
Thanks
I am talking about supply chain, so that the new research scholar will be of great benefit. After reading that, he was able to do a lot of improvement in his research.
31 December 2020 933 4 View
During the paper submission
22 December 2020 5,788 4 View
I wanted to use CCD aur box-behnken design Which one is better and how I can do experiment using design expert software
13 December 2020 6,323 5 View
Hello all, Is it possible to use lactose instead of IPTG for M9 protein expression? Glucose is traditionally used as the carbon source for labelling proteins and we used 2% final in the media....
14 October 2020 3,584 4 View
The adoption of bio-intensive cropping systems has the potential to reduce environmental footprints without compromising the economic gain per unit of resources.
12 October 2020 2,625 7 View
Polyhalite is a multi-nutrient source, its application assume to be changes the soil biology and nutrients chemistry on long term basis
12 October 2020 6,685 3 View
Hi, I am working on HK-2 cells and want to check for MDA accumulation after treatment with our compounds of interest. I am using MDA assay kit from Sigma. However, the kit does not mention about...
03 September 2020 1,795 2 View
An Invitation For the global health security, developing a One Health Biorisk Management (BRM) community of practice is essential. In this line, Vietnam One Health University Network (VOHUN) in...
28 August 2020 3,730 2 View
I have prepared line density map using ArcMap line density tool, what is the unit of output density map
06 August 2020 3,472 4 View
The mass advocation of micro-irrigation in India is a good policy for water resource conservation. Since the country is facing the problem of surplus management. Is it not the chance of...
06 August 2020 8,075 1 View
Hello, We would like to increase the yield of our PCR product. We are running a series of PCR reactions that is targeting ~1.1kb sequence. We begin each reaction with ~400pg of template DNA...
02 March 2021 4,029 3 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
To dear Researchers, I was analyzing a series of concentration for estimation of Real-Time PCR efficiency. The concentration was 1:10. I used MS-excel to evaluate Slope. The result of slope was -8...
01 March 2021 8,683 4 View
Does anyone have the experience of using Taq Man probes in the QIAGEN Rotar- Gene qPCR machine?
01 March 2021 5,311 1 View
Dear All, mirna primer showing some problem in the melting curve? any idea why? As attached is the melting curve. The forward sequence is obtained from miRBase and reverse primer is universal.
28 February 2021 5,008 4 View
I performed site directed mutagenesis, transformation, and then I sent out plasmids for Sanger sequencing and found out that there is extension of DNA just before the stop codon. I am not sure...
27 February 2021 547 3 View
Hi, my question is about the heating of thermal cycler machines and I hope some of you had experienced a similar thing previously. There are two thermal cycler machines in the lab(BioRad) and for...
26 February 2021 4,777 4 View
Hi I am a bit confused. They are asking me to find out the volume of DNA required in ul (a total of 30-100 ng for genomic DNA) from the DNA concentration in the nanodrop reading which was 404.8...
26 February 2021 5,029 2 View
Hi everyone, Illumina provides a list of primers to amplify with high taxonomic coverage the ITS1 region for further fungal sequencing, but I cannot find the exact amount necessary of each...
25 February 2021 6,969 3 View
After transfection with the plasmid ( linearized ) and subcloning of the cell lines, RNA was extracted from the cell and then reverse transcripted to cDNA. When PCR reactions were run to verify...
25 February 2021 5,712 3 View