every time whenever I prepared a binder-free electrode I get different mass loading ..is there any way to get constant mass loading on Ni foam?? how to control it??
Cell Cytotoxicity
24 June 2024 7,671 2 View
Dear Professor(s), I am looking for Post-Doc position or visiting researcher position on funded project based. If any professor has open position for international students, I will be happy to...
23 June 2024 9,619 1 View
sample preparation for penetratin (RQIKIWFQNRRMKWKK) by SPE before analyzing on LC-MS/MS?
23 January 2024 1,939 1 View
The photocatalysis was done using nano zinc oxide coated activated carbon at neutral pH using 0.3g of catalyst. Eventhough the solution doesnt show full decolourisation(it shows pale blue colour)...
17 January 2024 5,648 6 View
Hello Dear All I am a new user of VASP (Vienna ab-initio simulation packages) and tried to calculate the phonon using VASP. I get the phonon band structure (after calculations) in image form(.png...
11 December 2023 9,204 6 View
I have encapsulated Paclitaxel inside a polymer. The polymer is attached to different functional groups. I am getting higher values for optical density. Those values are not lying within the...
12 July 2023 6,830 0 View
I am currently working on the project of encapsulation of Paclitaxel inside polymer. I am getting higher values of OD like 3.044. So, I wanted to do quantification of drug using beer's law....
02 July 2023 5,204 2 View
i could not find out JCPDF card for XRD results of this compound in xpert high score. how can I interprete this?
18 May 2023 8,293 2 View
I am working on hydrophobic drug. DMSO is used as a solvent, when OD is taken it give me larger value. what is the best possible way to get appropriate value and nullify DMSO OD. Regards Nabeela...
06 May 2023 3,160 1 View
In the acid hydrolysis step of nano cellulose extraction , recent literatures are citing oxalic acid treatment in comparison with sulphuric acid
26 April 2023 6,014 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
I'm working on the atmospheric water harvesting, and i synthesized MOF by adding some materials into precursor and changing the conditions. (i followed Hydrothermal method) Actually, if MOF is...
24 July 2024 1,515 0 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View
Thanks
22 July 2024 1,143 3 View