• you have provided information on fibre types but not the fabric structure - woven, knitted or non-woven?
• the number of cycles required will depend on the purpose for undertaking the test - are you trying to show a typical response/life performance or are you seeking to demonstrate compliance with the standard?
No standard time is mentioned. It totally depends on the end use of the customer. You need to mention in the report : 14.1.3 Exposure cycle, for example, 4 h UV/60°C, 4 h CON/50°C.
14.1.4 Total exposure time
Example:
Exposing samples to 42 cycles of 8 hours of UVA-340 ultra-violet light at a temperature of 60C followed by 4 hours of condensation (dew) at 50C for a total of 21 days of exposure.