Hello everyone

I'm searching on a method to determine anode life which contains RuO2 (ruthenium oxide) as MMO. Based on NACE Standard TM0108-2012, the anode fails in a short period of time because ruthenium in the MMO coating dissolves in the acid solution. So that this is not an appropriate test method. Could you suggest an alternative method?

I want to test an MMO anode to electrolyze seawater and produce Sodium Hypochlorite (NaOCl) with a concentration1500-2000 ppm by the electrolyzer.

More Arash Motevalian's questions See All