Is it possible to get transmission characteristic curves using Optifdtd software. I tried but failed.
What could be the possible reason for not getting proper band of ladder while performing PAGE
07 June 2023 7,641 1 View
What will be the condition that s11 will be the same? I have tried to replace copper with graphene, but the results are very different. I also changed the chemical potential from 0.1eV to 0.5ev,...
24 May 2023 5,804 5 View
How can we make a pin diode in ON/OFF state based on the values of RLC. I have studied that in ON state RLC operates in series and in OFF state it operates in parallel circuit. I am attaching the...
07 March 2023 7,784 7 View
How do we maintain the HPLC column usage log? Except excel and smart sheets, are ther any alternatives?
17 January 2023 8,532 4 View
Is it possible that ZnO/CNT nanocomposite does not show supercapacitor applications?
02 January 2023 455 5 View
I designed an antenna by randomly selecting the L-shaped slot on the patch and ground plane. But is there any method by which we can select a specific shape of the slot to obtain multiband...
17 December 2022 6,995 7 View
Group delay is used to measure the response in the ultra-wideband region. Can it be a good parameter to analyse the performance of a narrowband antenna? If yes, how? Please share your views on the...
01 September 2021 7,894 7 View
What will be the direction of electrons/holes in the conduction/valance band of HIT or Carrier Selective Contact (MoOx and NiOx) based Si solar cell for diffusion-limited/thermionic charge...
23 March 2021 3,257 3 View
There is confusion regarding the submillimeter-wave range. Many papers specify its range from 300GHz but some also consider its range from 100GHz. If I design an antenna on 122ghz what would I...
01 March 2021 1,069 7 View
I am attaching my design and result of Gains.S11 parameter is less than -10dB from 3.1 to 9.8 Ghz.Z11 magnitude also lies between 40 -60 ohm for this range .Still gain is negative. Pls help
29 January 2021 4,630 3 View
I have virus (viral hemorrhagic septicemia virus) in suspension and the experiment will not involve cells. What level of TCID50 is preferred?
11 August 2024 3,115 1 View
Hello dear colleagues, We have prepared a manuscript on NiTi-based alloys and are seeking a second opinion on our current TEM results. If you are a Ph.D. holder with experience in TEM and have...
07 August 2024 9,563 0 View
average particle size calculation from TEM
04 August 2024 2,921 1 View
Previously, I successfully modelled the transmission and reflection of electromagnetic waves incident on non-magnetic materials. Please refer to my publications for details: 1- A polynomial model...
05 July 2024 1,396 2 View
I need to do TEM analysis for my Polyaniline emeraldine salt form. May I know which solvent is appropriate for preparing TEM sample?
25 June 2024 9,086 3 View
I need this complete article, could anyone help me? follow theme below. Chikungunya virus cell-to-cell transmission is mediated by intercellular extensions in vitro and in vivo.
20 June 2024 3,373 1 View
I have got crystalline size around 15nm from xrd but TEM is giving particle size 4nm
20 June 2024 6,064 8 View
I wanted to take tem images of my magnetic nanoparticles prepared using iron. It has a magnetic susceptibility below 10 emu/g. Whether this will interfere with the electromagnetic lenses of TEM...
14 June 2024 5,163 4 View
I am currently seeking software capable of calculating audible corona noise in HV overhead transmission lines under various meteorological conditions. I would greatly appreciate any...
10 June 2024 1,305 0 View
TEM imaging
30 May 2024 3,800 2 View