Hello everyone! I am doing half strip test for Lateral low immunoassay.

Here is my detail information about the experiment:

1. Size of Gold nanoparticles that I used is 15 nm.

2. GNPs solution was replace with Borate Buffer 0.01 M pH 9.0

3. Dilute MAb 0.1 mg/mL, incubate for 45 min

4. Add BSA 1%, incubate for 45 min.

5. Resuspend in borate buffer 1 mM pH 9.0

For immobilized antibody:

In the test line, I put my capture MAb 0.1 mg/mL

In the control line, I put my capture PAb 0.1 mg/mL

I have tested with varied MAb 0.1-0.5 mg/mL in the test line but the test line not getting colored even I applied antigen 10.000 ng/mL

For the control line, with PAb 0.1 mg the test line was getting colored.

Any suggestion would be very helpful for my experiment.

Thank you