The electrolyte consist of 95 ml Ethylene glycol, 0.7 g NH4F and 5 ml distilled water. Anodize at 60 v for 1 h. Previously, my TiO2 sample was ok, no erodation. But recently when I want to try again the experiment under exactly same condition,same power supply, the samples eroded. The current goes up to 0.1 A compare to 0.05 A before this. Any idea where I get wrong? Why the current increase?

Thank you for your answer :)