Finite element analysis of RC memebers subjected to shear and torsion show stiff model as compared with test results
its due to the phenomena of strain softening
Microcracks are not considered
https://www.youtube.com/watch?v=WLEkC_JbTsQ
03 April 2017 1,021 2 View
02 March 2017 8,545 19 View
Why 0.2 mm crack width?
02 March 2017 9,166 3 View
How we can design box girder bridge?
02 March 2017 9,977 3 View
How does rust affect on the bonding between steel bars and concret?
02 March 2017 3,267 10 View
02 March 2017 415 2 View
Can we use same code provisions of columns for piles?
02 March 2017 7,705 3 View
Relation between cubes and cylinder
02 March 2017 5,645 4 View
Non destructive tests
02 March 2017 5,232 31 View
Some codes provisions refer to this type of analysis.
02 March 2017 8,549 5 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I have conducted and published a systematic review and meta-analysis research with the topic related to public health and health pomotion (protocol was registed in PROSPERO). Now we want to...
03 March 2021 8,920 3 View
dear community, my model is based feature extraction from non stationary signals using discrete Wavelet Transform and then using statistical features then machine learning classifiers in order to...
03 March 2021 6,994 5 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
Hi, I am trying to construct a multi-layer fibril structure from a single layer in PyMol by translating the layer along the fibril axis. For now, I am able to use the Translate command in PyMol...
02 March 2021 4,569 4 View