I have a question that i would like to ask you.

I was working on a protein, Tau441, purification project. At the end I wanted to measure the concentration of the purified protein. I used SpectraMax device to check Absorbance at 280nm wavelength and got a concentration of about 0.8 mg/mL after calculations. I also did BCA assay and used the same device to read the absorbance at 562nm wavelength and got a much lower concentration 0.14 mg/mL. Which method is more accurate in this case?

My protein is Tau441 and the sequence is below:

MAEPRQEFEVMEDHAGTYGLGDRKDQGGYTMHQDQEGDTDAGLK

PLQTPTEDGSEEPGSETSDAKSTPTAEDVTAPLVDEGAPGKQAA AQ

PHTEIPEGTTAEEAGIGDTPSLEDEAAGHVTQARMVSKSK DGTGSDD

KKAKGADGKTKIATPRGAAPPGQKGQANATRIPAKTPPAPKTPPSSG

EPPKSGDRSGYSSPGSPGTPGSRSRTPSLPTPPTREPKKVAVVRTP

PKSPSSAKSRLQTAPVPMPDLKNVKSKIGSTENLKHQPGGGKVQIINK

KLDLSNVQSKCGSKDNIKHVPGGGSVQIVYKPVDLSKVTSKCGSLG N

IHHKPGGGQVEVKSEKLDFKDRVQSKIGSLDNITHVPGGGNKKIETHK

LTFRENAKAKTDHGAEIVYKSPVVSGDTSPRHLSNVSSTGSI DMVDSP

QLATLADEVSASLAKQGL

Thank you.