I know the software is non-commercial and offered free of charge. Yet I'm having a hard time finding it.
http://lansce.lanl.gov/lujan/software/popLA/popLA.shtml
Thank you guys. I forgot to mention that I had sent them a few emails without getting any answer. I'm not sure if anybody checks that account at all.
Be patient. The Lujan Center has other issues going on these days.
http://lansce.lanl.gov/lujan/index.shtml
I has been trying to obtain the package by sending an E_mail. I think they do not answer because I'm Iranian!
Hello All, In order to make some calcium test devices, we will be needing to expose calcium pads (100 nm of thickness) to nitrogen atmosphere. We do not expect the exposure time to be more than a...
08 September 2019 1,313 4 View
Does anybody have any experience with evaporation of organic materials, and the most suitable type of QCM for thickness control? I'm getting very low repeatability in growth rate, and I'm...
01 February 2019 9,655 2 View
In order to verify the epitaxial nature of the thin films, one can perform a phi scan. The distribution of a certain omega-2theta peak along phi will be indicative of the two-dimensional...
04 May 2014 7,235 2 View
I am looking for a software package for building and analysis of pole figures in thin films. I'm having a hard time finding the PoPLA software. What alternatives would you suggest?
03 April 2014 2,943 2 View
I have GaN and AlN films ranging from 10 nm-150 nm in thickness. For the thicker films, I can use the general theta-2theta coupled scan. But for the thinner films, I have to use the grazing...
03 April 2014 9,273 1 View
When using a two-dimensional detector, Bruker Discover machines can give a two-dimensional "GADDS Frame" that shows intensity as a function of 2theta and chi. Now the software does not have any...
03 April 2014 1,108 8 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
I need to model an anisotropic material in which the Poisson's ratio ν_12 ≠ ν_21 and so on. Therefore, the elastic compliance matrix wouldn't be a symmetric one. In ANSYS APDL, for TB,ANEL...
09 August 2024 5,048 2 View
Require for Rietveld refinement in XRD.
08 August 2024 3,081 2 View
After performing symmetric PCR, PCR purification was performed. Afterwards, asymmetric PCR was performed using the PCR purification product as a template, but no ssDNA band was confirmed in the...
08 August 2024 1,668 3 View
Hi! So i attempted to understand a novel protein behavior towards heat application by analyzing its secondary structure change. I subjected the protein to a thermal denaturation analysis using...
06 August 2024 1,989 3 View
How can I measure the thickness of thin film by Uv-Vis?
06 August 2024 7,810 3 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I am working on Abaqus/Explicit(Quasistatic ) for the deformation of the auxetic structure model. Please explain how the plastic input value should be considered from the true stress-strain curve...
05 August 2024 454 3 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View
Why is TLC not a form of partition chromatography and paper chromatography not a form of absorption chromatography?
03 August 2024 7,035 3 View