Swamping and masking are caused by input data that is too large for the purposes of anomaly detection.
I think Subsampling would be the better approach.
Please go through my Abstract. I can also share a proposed Thesis Outline.
04 August 2024 2,077 0 View
For example, oxazine type moieties which forms diastereomers, how the separation can be done? Chiral HPLC is the only possibility?
10 July 2024 1,519 3 View
We submitted an article to a journal, which subjected it to a plagiarism test. Afterward, we withdrew the paper and submitted it to a different journal, only to discover it now has a very high...
07 June 2024 4,688 3 View
La juventud dominicana necesita la inclusión en la producción de bienes que satisfagan necesidades humanas en su contexto local, desde la formación y el desarrollo del emprendimiento en una...
01 June 2024 8,956 1 View
Good day! I am currently testing for the antioxidant activity of my extract via the hydrogen peroxide scavenging assay. I have already done the experiment in six trials using 30% hydrogen...
27 May 2024 4,677 3 View
Hello everyone! I am currently working with the model organism Ectocarpus (filamentous brown algae). Our team is trying to standardize a protocol for RNA extraction using low biomass (around 10...
18 May 2024 3,862 1 View
The format to requests has changed. I simply want to respond to a request and can no longer find any way to do this. The 'help' section regarding this is 2 months old. Thanks, George
30 April 2024 250 0 View
The harsh reality facing the world and migrants majorly is the wide economic disparity and Inequality fuelled by some rich world economies exploring resources and failure to meet social...
09 April 2024 1,420 0 View
Is there any method validation procedure for toxicological studies like Implantation, Acute toxicity, skin sensitization, irritation on animals. Generally these studies will conduct on animals.
28 March 2024 280 0 View
I run an Agilent Technologies Graphite Furnace and a recurring problem when analyzing Lead is that the continuous calibration verification, (CCV), QC slowly drifts lower from the target (20ug/L)....
27 March 2024 3,609 0 View
Hello, Can anyone provide me with the absorption coefficient of methane gas at 7.7 um? Any reference?
06 August 2024 980 5 View
What types of mask designs for metal deposition, to be used in a PVD system, are best suited for perovskite-based solar cells?
31 July 2024 4,835 3 View
The indexes NDWI and MNDWI are use to identify waterbody. Can I use these index to identify wetland also? Thank you for advance.
25 July 2024 6,242 2 View
I know the difference between instrumental LOD and method LOD but my query is - in case of any sample whose concentration is zero or not detected by the instrumental LOD, is it possible to get...
24 July 2024 6,592 5 View
I am performing fluorescence experiments using a ligand to detect metal ions. I want to determine the Lowest Detection Limit (LOD) using the formula LOD = 3σ / K. However, I'm uncertain about...
19 July 2024 1,086 1 View
I am working on flourescence sensing of heavy metals using quantum dots.Can any of you suggest how to find the detection limit. Whether it is calculated from formula or we can get from instrument?
19 July 2024 7,411 3 View
Anomaly detection in scanned image data set
18 July 2024 3,578 3 View
We have mice brains that were over-fixed due to old PFA used during perfusion. Thus, the synapses are no longer being labeled by the Synaptophysin (SY38) mAB. which works perfectly every other...
17 July 2024 7,767 3 View
I work with planar interdigitated electrodes (IDEs). The finger width and the spacing between the fingers are 5 micron. The surface of the IDEs is coated by a non-conductive polymer layer...
16 July 2024 5,031 1 View
I am trying to configure the instrument in Profex but I can't get a chi-squared value below 9.65 for LaB6. This is the configuration of the equipment, which is a Bruker D8 Advance with a Linxeye...
14 July 2024 4,767 1 View