I want to look at the genotoxicity of my coating material to mammalian cells. From whatever I have seen so far, the tail moment is commonly used. What else is considered standard?
For Comet assay? OTM is the best way to represent data. You can also use RAPD, to detect genomic damage. Also Southern using probe for repeat elements like LINE-1 can also be done.
Although there are several endpoints for the Comet assay, the maojority of authors recommend the use of the DNA content in the tail (% tail DNA) to assess DNA damage.
hi, many comet indexes used in comet analysis(about 15 to 16 index). But the most important indexes is five index includes: comet length, comet height, tail length, % DNA in tail and tail moment. In More Articles, % DNA in tail and tail moment used.
the best, simple and free software for comet assay analysis is comet score program.