(vid. attached images) The Isc and Voc are as expected, but the initial curve appears to show a decline as the voltage increases, which is characteristic of a high resistance and low FF, but suddenly the curve spikes just before the MPP and then, as normal, drops down the Voc. What is causing this spike?

I am using a Keithley 2420 SMU for a 4-wire IV characterisation. Illumination is by a tungsten lamp. Multiple PV cells have been tested. The cables have been changed. Both Kickstart and LabVIEW have been used to automate the SMU. Different manufacturers' PV ribbons have also been tested. None of these changes have had an effect and the kink in the curve persists.

Multiple cells of the same have been soldered type in series as well, since one module made up of nine series-connected cells provided by another researcher from a different laboratory does not exhibit this IV kink. We think this module was made from the same batch of PV cells but are not 100% sure; the manufacturer is definitely the same though. Nevertheless, the same cells soldered in series at our lab still exhibited the same kink in the IV curve.

Thank you