It is very important to monitor all the devices in adhoc network as well. Due to increase in the demand of the MANET, necessity to monitor such network has been increased.
Respected all, I want to know about the correct method to find out the residual stresses in the carbon fibre reinforced composites. The literature says that XRD can get residual stresses. However,...
30 January 2020 486 13 View
when light falls on the extrinsic semiconductor, % increase in minority carriers are higher than majority charge carriers, please explain why ?
01 September 2018 901 2 View
I'm targeting to deploy a mesh network and manually configure MANET routing protocols. I'm preparing scenarios, architectures, and hard devices needed to do that. Are there some step-by-step...
03 March 2021 1,931 5 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...
02 March 2021 1,408 1 View
Hi Community, I'm facing the issue of integration/compiling a new routing protocol in a WSN simulator. The final goal is to successfully add, configure this routing protocol in hardware devices...
01 March 2021 9,332 6 View
I am designing a small grid connected solar PV power-plant. As the battery's capacity is specified in Ah and demand in kWh. What is the best way to size the battery bank? I have battery price in...
28 February 2021 1,638 3 View
I am trying to obtain the response and recovery times for my gas sensor device. It appears the the response/recovery times are primarily dependant on the flow rate of the gas I inject into the...
26 February 2021 1,511 3 View
Hi, everyone I'm working on a privacy-preserving algorithm that will apply to IoT devices. So, I need to measure the power consumption by implementing this algorithm. Any suggestion, advice,...
25 February 2021 8,749 6 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
Hello researchers! While studying the literature on refractive index sensors, most of the articles simulate their devices with a refractive index ranging from 1 to 1.1, with small steps in...
17 February 2021 1,578 4 View
I tried to sweep my ferroelectric devices from -2V to 2V and then from 2V to -2V and The two hysteresis peaks are off by several microFarads. Should i increase bias voltage? I am doing these...
16 February 2021 8,514 2 View
The data collected from various measurement devices often contains erroneous values - such as noise, missing values, etc. What are the popular techniques for pre-processing measurement data in...
14 February 2021 4,642 2 View