Reference electrode solution:AgNO3(0.01M)/TBAP(0.1M)/ACN
Electrolyte: Ferrocene(2mM)/TBAP(0.1M)/ACN
Sri Vidya Cherukuthota
The reason for the bias is that you are not reaching equilibrium in the redox reaction. If equilibrium is reached, the concentrations of substances remain constant. Consider what is being removed from the reaction zone.
I have a theoretical framework for preparing a interview guide to assess the unmet care needs of a sub population of chronically ill patients and their caregivers(dyadic interviews).
04 August 2024 8,798 7 View
FYI Catalyst is MFI zeolite Si/Al = 140,25.40.11.5,15 I am using this catalyst to study methanol to DME conversion
25 July 2024 2,486 2 View
I am trying to write a detailed article Secondary Data Methods
20 May 2024 2,109 3 View
There are 33 items adding up to an overall value for qol score. How to present the results of two-step cluster analysis in the methodology for differentiating cases and controls group? Should any...
14 May 2024 7,717 2 View
Les say you have a data that is has more noise and now you will need to decide which data analysis technique will be more useful and how do you start data visualization.
09 May 2024 8,935 3 View
Dear friends, I am looking to develop a new project for the applications of displays using float glass. How and what process is needed to develop such flat panel displays what are the ideas and...
09 May 2024 3,233 0 View
Hlo I am trying to get kinetics of methanol to dimethyl ether kinetics on hzsm-5 si/al = 40 catalysts at 160 deg c I was unable to reach zeroth order kinetic regime. I am doubting that the...
05 March 2024 1,930 0 View
Dear ResearchGate colleagues, professors, and scientists, I'm encountering challenges with coated thin films produced using a sputtering system. Following treatment through tempering at 650...
11 February 2024 3,585 4 View
I have synthesized gold nanoparticles that show UV Vis peak at 522nm and were bright pink immediately after synthesis. Over a span of 24hrs, the Solution shows visible colour change from pink to...
07 February 2024 10,125 5 View
Hello scientists I am PhD student in united states workin in acid sites characterization in zeolites. I am using methanol as a probe molecule to investigate the acid sites in zeolites. I am using...
24 January 2024 9,936 4 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
Hello. I am working on ROS production of two systems: system A is cerium oxide and hydrogen peroxide, system B is cerium oxide nanoparticle, hydrogen peroxide and potassium bromide. I did some...
04 August 2024 5,974 3 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
Why BaO (s) + H2O(l) ---> Ba 2+(aq) + 2 OH - (aq) if Oxygen loves owning all the electrons, why would it bind to hydrogen which competes with Oxygen for electron ownership more so than...
03 August 2024 5,392 1 View
I imagine the battery drives the graphite into a carbocation, then chloride is oxidized to donate the electron to the carbocation, but what pushes the lost electrons of chloride to be shared...
03 August 2024 5,384 0 View
How to calculate the molar proportions of the oxides from the XRF analyses?
02 August 2024 2,565 2 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.