Hello All,
I was just trying to run a model with pore pressure cohesive elements. When I have the surrounding matrix with low permeability (i.e. of the order of E-15 to E-17 m2) value, the simulation aborts? Any suggestions?
Thanks,
Aditya
Hello, I was just thinking if it could be possible to connect two cohesive planes in Abaqus? Thanks & Regards, Aditya
08 September 2015 9,981 1 View
Hello, I am trying to run .inp file and .f file from an example in Abaqus Manual. I have attached link to this question! I have made the necessary changes to be made in the .inp file as per the...
06 July 2015 5,588 16 View
Hello, I am trying to link Intel Fortran, Visual Studio and Abaqus. I installed as per the below sequence Abaqus 6.14-2 Visual Studio 2013 Community version Intel Parallel Studio XE 2015 Update 4...
05 June 2015 493 3 View
I need to model an anisotropic material in which the Poisson's ratio ν_12 ≠ ν_21 and so on. Therefore, the elastic compliance matrix wouldn't be a symmetric one. In ANSYS APDL, for TB,ANEL...
09 August 2024 5,048 2 View
I have input a moment load in module load Abaqus, i put my moment load on the node surface (using reference point). I have define moment in history output and make a set for moment too. But the...
08 August 2024 4,831 4 View
One can try to generalize the Vandermonde determinant in the following direction: Let $A$ be any symmetric $n$-order square matrix. Consider its powers' diagonal elements $(A^k)_{ii}$ and...
08 August 2024 6,690 1 View
I have modelled a steel structure using beam elements in Abaqus and attached to this structure reinforced concrete slab. The analysis that I am making is heat transfer of the structure. The...
07 August 2024 1,028 0 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
I am working on Abaqus/Explicit(Quasistatic ) for the deformation of the auxetic structure model. Please explain how the plastic input value should be considered from the true stress-strain curve...
05 August 2024 454 3 View
Have you ever seen a LC-MS/MS method uses both internal standards and external standards (in matrix matching purpose) but the concentrations of internal standards are outside the calibration curve...
05 August 2024 3,084 6 View
Hello guys! Do you have experience running a Oaxaca-Blinder decomposition on R applying person weights. How do you suggest doing it? I have a variable PERWT which gives more information on how...
04 August 2024 6,033 0 View
- The Existence/Uniqueness of Solutions to Higher Order Linear Differential Equations - Higher Order Homogenous Differential Equations - Wronskian Determinants of $n$ Functions - Wronskian...
03 August 2024 2,366 0 View
I need to lyse and homogenise mouse tissues. So far I have experimented with liver and lung tissue, using matrix D. The liver was completely lysed with 6 repetitions of the standard program, but...