Hi, We are following 4days incubation of 15N2 into 20mL sealed vials. Could advise, is samples required immediate oven dry after remove incubation of 15N2 or vials can put open for some of the days, it may not change results of nitrogen fixation?
Please, if Gaussian Parameter optimization is possible in this code structure
28 February 2021 278 3 View
The solar photovoltaic (PV) power plant uses commercial (non-concentrated) PV modules which are quite simple in design and reliable. They can work on fixed orientation and don't need the moving...
16 February 2021 3,796 9 View
Dear Sir/Madam I want to use Sine voltage as a source in an RLC circuit. I want to study the driving point impedance with frequency sweep. But when I use sine voltage, I get an error like The DAE...
13 January 2021 9,826 5 View
Hi everyone, Happy New Year! I am carrying out a Simulation for Flow Past a Square Cylinder. I am using Ansys Fluent. I get a very low value of Cd in the simulation. The solution converges but...
03 January 2021 4,389 3 View
I am using a very fine mesh (D/1000). Since I cannot find an option to turn off the wall function in Fluent GUI, could you please let me know how I can turn it off? From some forum I got to know...
21 December 2020 9,186 15 View
I am trying to find out the inverse Laplace transform of the state transition matrix obtained using inv(S*I-A). Where I is the identity matrix, and A is a state-space matrix(24x24 matrix). I have...
21 December 2020 7,041 3 View
Hi everyone, any insight is appreciated. I am simulating with a D/1000 [first boundary layer height] mesh the flow past a square cylinder (inside a Circular domain). For Coarser mesh, I had no...
21 December 2020 5,438 10 View
Dose conversion from rat to mouse?
23 November 2020 1,807 3 View
For my research purpose, I need the name and optical properties of the glass used on the front surface of the solar panel. Can someone provide me the aforementioned data with valid references? Is...
22 October 2020 9,714 9 View
I have 2 models where the first model is a subpart of the second one. The components of the subpart have the same mesh and geometry in both the models. I have performed stress analysis on the...
18 October 2020 9,256 5 View
Excessive rotation of nodes in node set ErrNodeExcessRotation-Step1
17 August 2021 0 0 View
20 June 2021 0 0 View
--> FOAM FATAL ERROR: Maximum number of iterations exceeded From function Foam::scalar Foam::species::thermo::T(Foam::scalar, Foam::scalar, Foam::scalar, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar) const) const [with Thermo = Foam::hConstThermo >; Type = Foam::sensibleEnthalpy; Foam::scalar = double; Foam::species::thermo = Foam::species::thermo >, Foam::sensibleEnthalpy>] in file /home/ubuntu/OpenFOAM/OpenFOAM-4.1/src/thermophysicalModels/specie/lnInclude/thermoI.H at line 66. FOAM aborting #0 Foam::error::printStack(Foam::Ostream&) at ??:? #1 Foam::error::abort() at ??:? #2 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::calculate() at ??:? #3 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::correct() at ??:? #4 ? at ??:? #5 __libc_start_main in "/lib/x86_64-linux-gnu/libc.so.6" #6 ? at ??:?
24 March 2021 0 0 View
Beginner level books. High level books. Analytical Number Theory. Algebraic Number Theory. Combinatorical Number Theory. Books about partitions. Books about primes.
03 March 2021 7,174 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello, good day! I am trying to simulate similar bimorph piezoelectric harvester with below commands. However, the output power doesn't change with resistor value. Please help to find the reason. ET,10,CIRCU94,0 !SET UP RESISTOR R,1,100000 !RESISTANCE VALUE TYPE,10 !SET ELEMENT TYPE E,1,2 !CREATE RESISTOR BETWEEN NODES 1 AND 2 Thanks in advance Regards,
02 March 2021 0 0 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
Question to you and THEM, the New Journal, "Integrative Psychological and Behavioral Science" -- do you not know, and have you not seen, this done before? There appears to be a core problem for...
02 March 2021 3,024 2 View