Hello,
I want to model a parabolic hole in a slab using ABAQUS. Can i do it? if Yes how?
Hi Prashant
yes, it is possible.
1) in the part module select the slab,
2) in the left ribbon options, select the "cut extrude"
3) you will be gone back to the sketch part
4) draw your section
5) Done.
Best Lucks
hello sir,
thank you for the reply, i understand what you said, but even then i think you cannot create a circular parabolic duct at the center of slab.
Can you please draw a sketch? I am not able to get what exactly are you looking for.
SURE SIR
In the part module
1. Shape menu (at the top) > Cut > Sweep.
2. In the appeared menu,
(i) Sketch the path, i.e. parabola along the slab
(ii) Sketch profile, i.e. circle on the face normal to the path
You will be get it.
Exactly.
Plz follow the Mr. Faye instruction to approach your goal.
Dear Mr Faye and Mr Ghaedi.
Thank you for taking out time and replying
Yes its working this way but sir again how do i define the sweep at the center of slab. it is only possible to sweep cut on the faces this way.
Sweep path is independent of the sweeping geometry. You sketch the sweep path at the face and sweeping circle at the center of the slab. That should not be a problem.
I am doing buckling analysis of laminated plate surface bounded with two piezoelectric PZT 5H and axial compressive load is applied. I am getting an error, No ANEL table exists for material 2....
16 February 2021 510 1 View
My question is very specific about melting of pure reduced Iron Fe in powder form
29 December 2020 4,352 3 View
Autocorrelation value is 0.3 and input cross-correlation error value is 3.Are the obtained results after training ANN is correct or wrong?
04 October 2020 9,686 2 View
I want to do docking of Poly ICLC with protein. But, unfortunately there is no crystal structure for Poly ICLC or poly IC. Poly ICLC is a complex of Poly IC, poly lysine, and...
24 September 2020 6,107 1 View
The sample (fungal RNA) extracted with RNeasy Kit is supposed to be sent for sequencing.
15 September 2020 7,128 3 View
I have an MR Dicom file having values of repetition time, echo time, Inversion time, flip angle, etc. I want to calculate T1 and T2 from this Dicom file. Is there any way to calculate this from...
12 March 2020 7,598 12 View
Wanted to compare the behaviour between ductile and non ductile detailed RCC frame specimen
04 February 2020 270 2 View
I have injected 5 samples of lowest possible concentrations. I have taken the std deviation of area and slope of the equation obtained for the regression line of calibration to calculate LOD &...
19 January 2020 4,730 7 View
Hi, I am looking for a tool to measure the start and end of xylem tissue in plant and tree. Please send the link if such product (s) are available commercially. Thank you
18 January 2020 8,808 0 View
03 January 2020 1,399 2 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I have conducted and published a systematic review and meta-analysis research with the topic related to public health and health pomotion (protocol was registed in PROSPERO). Now we want to...
03 March 2021 8,920 3 View
dear community, my model is based feature extraction from non stationary signals using discrete Wavelet Transform and then using statistical features then machine learning classifiers in order to...
03 March 2021 6,994 5 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
I am wanting to calculate the average trend in maximum annual NDVI in Iceland from 2010-2020 using MODIS MYD13Q1 V6. How would I do this? I have currently inserted the NDVI bands from the MODIS...
02 March 2021 752 2 View