Is it okay to use NanoDrop Lite Spectrophotometer to determine UV range of conjugate and toxin? Please comment if any other suitable method for conjugate detection
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
Actually, I am running cfd simulation for a heat exchanger which has two fluids one hot and other one is cold fluid. there is a solid domain between them, which I removed and instead I have used...
01 March 2021 9,537 2 View
I am simulating Heat Exchanger. I have tried and tested all the methods to resolve this issue from the internet like refining mesh, improving skewness and orthogonal quality ,extending outlet to...
01 March 2021 6,985 3 View
I have to amplify a gene and my primers just reached. The Tm for Forward primer is 64.2, and that of reverse primer is 65.5. Can some one suggest how to get the best annealing temperature? Thanks...
01 March 2021 360 7 View
Should I mesh the solid domain ? or should I use wall thickness? or Shell conduction? for Heat Transfer between two fluids of a Heat Exchanger. what is recommended?
01 March 2021 9,785 3 View
I have a virtual machine. My host Pc specs are not that good thats why i went for virtual servers. so basically my host pc has 8gb of ram with nvidia quadro k2200 4Gb DDR5 GPU ,processor intel...
01 March 2021 8,415 1 View
Is the period to autoclave not enough? The inoculation in a hood and flame and UV and alcohol.
27 February 2021 9,356 3 View
hello. i am junior researcher. I received a comment from a reviewer that he could not find NMR data in my submitted paper. I had included the NMR graph with explanation and formula to calculate...
27 February 2021 734 4 View
I have a sample of treated water sample & asked to obtain ammonia conc. in sample using a machine with 5-25 ppm detection range. However, upon testing with different dilution factors, all...
27 February 2021 8,483 3 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View
I have a protein with a 10xHis-MBP tag on the N-terminus. I'm fairly certain I am expressing my protein, but I'm not getting a signal on my western blot. Is there a possibility that the 10xHis tag...
25 February 2021 8,404 3 View
I'm currently working having problem with the concentration for recombinant protein use in western blot, the one been used is Recombinant Human CD19 Fc Chimera Protein-rndsystem which does not...
24 February 2021 8,514 3 View
Increasingly, more articles are being retracted because of duplicate or otherwise dubious Western blots. Consequently, journals are asking for original Western blots and authentication of...
23 February 2021 8,609 3 View
Hi Everyone, I am a bigginer in western blotting and I am trying to use it for validation of my proteomics data. I have: two regulated proteins with molecular mass of 40 and 73 kDa one control...
23 February 2021 6,671 4 View
I need help using the equation C1V1=C2V2 figuring out how much antibody to add to use for a western blot. The stock was origianlly 3.45 ng/ul but diluted 1:10 so now its 0.345 ng/ul. I need to run...
22 February 2021 9,901 3 View
I run western blot on HCT-116 cell lines, I got actin band like in the attached picture. The band size is not same. Can anyone help me explain this situation and how to overcome? Thank you your...
22 February 2021 6,937 3 View
I ran a western blot using 12% gel and probing for ERK/pERK (cell signaling antibodies). The green is total ERK, the Red is supposed to be phospho-ERK. I see 2 bands below the total ERK that...
22 February 2021 1,777 3 View
Could the "incoming solar radiation" values be negative? What is the difference between "global solar radiation" and "incoming solar radiation"? Which one might be measured negative values?
21 February 2021 7,726 9 View