My sentaurus simulation of solar cells usually don't converge at the part after the illumination. 

So before the doesn't converge part, the last successful part is the finishing of Raytracing part:

Summary of RayTrace Total Photons and Powers:

Input Escaped StoppedMinInt StoppedDepth AbsorbedBulk

Photons [#/s]: 7.392E+17 7.076E+17 2.989E+03

...

...

And then the next part is:

Starting solve of next problem:

Coupled ( Digits : 5, Max. #iterations : 30,

Solver : blocked decomposition,

#undamped iterations : 100

)

{ Poisson Electron Hole }

===============================

Computing Coupled( 1 poisson-equation(s) , 1 current-contact-equation(s) ,

1 electron-equation(s) , 1 hole-equation(s) )

using Bank/Rose nonlinear solver.

...

...

Finished because...

|RHS| increased to by more than 1e10.

So can someone tell me what is the problem here? I mean which part of the program is having problem and what kink of problem it is?

More Shujian Xue's questions See All
Similar questions and discussions