My sentaurus simulation of solar cells usually don't converge at the part after the illumination.
So before the doesn't converge part, the last successful part is the finishing of Raytracing part:
Summary of RayTrace Total Photons and Powers:
Input Escaped StoppedMinInt StoppedDepth AbsorbedBulk
Photons [#/s]: 7.392E+17 7.076E+17 2.989E+03
...
...
And then the next part is:
Starting solve of next problem:
Coupled ( Digits : 5, Max. #iterations : 30,
Solver : blocked decomposition,
#undamped iterations : 100
)
{ Poisson Electron Hole }
===============================
Computing Coupled( 1 poisson-equation(s) , 1 current-contact-equation(s) ,
1 electron-equation(s) , 1 hole-equation(s) )
using Bank/Rose nonlinear solver.
...
...
Finished because...
|RHS| increased to by more than 1e10.
So can someone tell me what is the problem here? I mean which part of the program is having problem and what kink of problem it is?