26 March 2021 3 6K Report

I was wondering if anyone had advice on removing a nickel hard mask - which seems to have become resistant to my standard Nickel etch. The sample is GaN with a hard Nickel mask, which has undergone AR-Cl ICP etching. Normally I would remove the nickel using a dilute (5-10%) Nitric acid etch, however it seems like it has become resistant to this etch.

I have also tried dilute Aqua Regia, a dilute Nitric + Acetic + Sulphuric acid mix, and eventually a concentrated Aqua Regia* (* NOT A GOOD IDEA - I got excited when it changed colour and started bubbling, but on inspection it etched everything EXCEPT the residue!)

My current theory is that during the ICP etch the Nickel has reacted possibly with the chlorine to produce NiCl. I have read that this can happen around 200C - which is a little above what the ICP set temperature is at 150C - however presumably the sample can heat up above this.

I was wondering if anyone has had similar issues - and/or if there were any wet etches I could try which would etch NiCl (should this be it).