28 February 2020 1 3K Report

I am simulating a glycerol-water mixture system in a square box of length 3.5 nm. After the NPT step my box size decreased to 2.62984 nm. However, in the beginning of the production run step I get the following error:

ERROR: The initial cell size (0.657461) is smaller than the cell size limit (0.683200)

Also, the log file says:

Initializing Domain Decomposition on 16 ranks

Dynamic load balancing: auto

Will sort the charge groups at every domain (re)decomposition

Initial maximum inter charge-group distances:

two-body bonded interactions: 0.390 nm, LJ-14, atoms 479 480

multi-body bonded interactions: 0.390 nm, Proper Dih., atoms 479 480

Minimum cell size due to bonded interactions: 0.429 nm

Maximum distance for 5 constraints, at 120 deg. angles, all-trans: 0.683 nm

Estimated maximum distance required for P-LINCS: 0.683 nm

This distance will limit the DD cell size, you can override this with -rcon

Should decrease the number of processors or just add -rcon in the mdrun command or perhaps do something else?

Thanks,

Sourav