I need to create ohmic (non-rectifiyng) contacts to a germanium wafers, using only manual tools, on an area of about 1 to 2 mm2.

The wafers are raw, P or N doped.

The procedure I use is the following:

  • Wetting the area with a few drops of very strong flux (for inox soldering)
  • Scraping the area with a surgical knife
  • Tinning the area with Sn/Pb 60/40 solder

However I cannot obtain consistent result and the joints are often very delicate.

Do you have suggestion for a better connection?

The sample has to be subject to thermal stress (cycled between -200 and +200°c in 1 hours a few dozen times).

Thank you in advance for your help

More Davide Bortolami's questions See All
Similar questions and discussions