I need to find out the maximum allowable strain of Piezoceramic (PZT) of NAVY II type
What about asking the supplier?
Dear Mostafa Sleem
You can perform a compression test if you have significant thickness unless an indentation test is highly recommended.
Good luck
I have a dataset with about 80 different species. As usual, some species are very easy to identify with certainty whereas others are more difficult, which means that I am less certain of my...
03 March 2021 8,066 4 View
I have prepared a manuscript in IEEE Latex template, but for some purpose, I need to prepare a word file as well (detailed format is not required). Compared to two column .tex file, one column...
02 March 2021 1,830 3 View
Gel electrophoresis, RNA degradation, RNA extraction from fresh tissue
02 March 2021 5,433 5 View
Hello, I would like to ask how to grow E.coli which resists 50 or 100ug/ml of Blasticidin. I have tried many methods by using low salt Luria-Bertain(LB) agar plate. However, no colonies grow. Let...
01 March 2021 2,027 2 View
I'm looking to try out an off-the-shelf EEG set for some exploratory work. Curious if anyone has used the OpenBCI, and how much set-up work is required. I've heard they are more difficult to get...
01 March 2021 4,128 3 View
I am doing a acid and a chiral amino alcohol reaction using DCC and HOBT in DCM or THF? Can anyone suggest me how to remove DCU and HOBT from a reaction mixture??
28 February 2021 2,153 1 View
Favourable conditions of base pressure, rate of deposition. Also, by which characterisation technique to be used to verify the thickness of the deposited film.
28 February 2021 3,640 3 View
The following code (see 1st 2 images attached) is used to produce PID controller values that are designed to control the system (G). The code finds the PID controller values (noted as k) by using...
28 February 2021 6,560 14 View
Hi everybody, I have been running a multiplex IHC which allow me to stain the same tissue with different markers (Primary Ab + Secondary conjugated Ab) (AF487, AF555, AF647). Since I would like to...
27 February 2021 5,028 2 View
What is the disadvantages of high sulfur content to the ceramic burning process? and what is the effect of outranged viscosity?
24 February 2021 8,219 2 View
I am doing buckling analysis of laminated plate surface bounded with two piezoelectric PZT 5H and axial compressive load is applied. I am getting an error, No ANEL table exists for material 2....
16 February 2021 510 1 View
I have a circular PZT layer deposited by PLD method. The dimensions are: 20um diameter and 350nm thick. It has 100nm Pt electrodes sputtered on the top and bottom. I would like to know what is the...
25 January 2021 688 5 View
What kind of press is using to make electroceramic parts, including PZT parts (hydraulic press, pneumatic press, etc.)? Furthermore, what is the reason for using this type of press? And does the...
28 December 2020 1,215 2 View
I am trying to model a piezoelectric sensor attached to an aluminum thin plate. I know that it is possible to model a PZT using Mechanical APDL, selecting the proper elements, such as PLANE13,...
13 October 2020 7,915 11 View
Hello, Recently I used the Positive Up Negative Down technique to calculate the polarization of PZT. After the experiment, I observed two unwanted current response peak which appears right before...
04 October 2020 6,736 3 View
I am doing modelling work of piezoelectric sensors bonded on the surface of the host structure. I have been doing this work in ANSYS APDL. I made three geometries for PZT patch, adhesive layer...
01 October 2020 2,412 8 View
I am doing modelling work of piezoelectric sensor bonded on the host structure. The size of the PZT patch & adhesive layer is 10x10x0.3 mm whereas the size of the host structure is quite...
29 September 2020 6,538 6 View
I am modelling a piezoelectric material bonded on the host structure & correspondingly I have to plot electrical conductance vs frequency plot. I have been doing the work in Ansys apdl &...
04 September 2020 8,626 3 View
29 January 2020 6,715 4 View
I need some information regarding a suggestion for piezo linear amplifier/High voltage amplifier suitable to operate at a peak voltage of 500V/mm for piezo ceramic patches (Rectangular C-91)....
27 November 2019 8,466 8 View