I am working on biosensor using silver nanowires. Does anyone have any idea how to chloridize silver nanowires for reference electrode?
It is sufficient to polarize it as an anode in a chloride-containing solution; I suggest you to maintain a small current value for a relatively long time (one hour)
Thank you all.
How about using Clorox (Bleach)?
Is it necessary to leave some portion of silver unchloridized (like the commercial reference electrode)?
How can I prove or test if there is actually silver-chloride? Is FTIR OK for that?
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
I want to analyses the proportion of swimming sperm of three species of fish in two salinities. To analyse the proportion of swimming sperm in a Generalized Linear Model, I would use a Binary...
03 March 2021 2,297 3 View
03 March 2021 8,272 1 View
Hi. Please tell me what guidelines should i need to follow for questionaries' type research work in India. It is not hospital based work, we are conduction basic institutional based qualitative...
03 March 2021 2,037 3 View
Hi, I implemented a code to gabor filter cifar10 data but the images after being filtered and stacked are not clear like the original images. I think the problem is in the way I am using the...
03 March 2021 6,317 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
03 March 2021 5,360 2 View
The term miscibility refers to the single-phase state in thermodynamics. I do not mean the compatibility of different components. To determine the miscibility I know several techniques such as...
03 March 2021 4,107 4 View
I have prepared a manuscript in IEEE Latex template, but for some purpose, I need to prepare a word file as well (detailed format is not required). Compared to two column .tex file, one column...
02 March 2021 1,830 3 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
I took measurements of different concentrations of 15 nm and 5 nm Au nano particle solutions. I'm trying to determine which concentration I measured gives the best reading overall. I also...
02 March 2021 7,626 1 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
In the stabilization of AgNPs are vital in current research interest. However, some of the 2D nano-materials like graphene oxide, MoS2, etc... previously used to stabilize it. But still they shown...
01 March 2021 2,207 3 View
What could be the reason of moisture at the sides of Vial when I am preparing my polmyer+DMSO solution for membrane fabrication? What etiquettes I am possibly missing here?
28 February 2021 6,516 5 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
Hi, I am trying to learn the theoretical modelling of silver nanoparticle using the Mie scattering theory. After that, I discovered a software named Mieplot developed by Philip Laven, where it...
25 February 2021 7,493 6 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
I notice that upon washing and air-drying of my RGO/SPCE surface and characterizing again via DPV, the current response towards ferricyanide probe significantly decreases. My worry is that the...
22 February 2021 5,324 3 View