Hi Samuel,
What kind of situation will cause the current leakage in Parylene insulated electrode ? film degraded or as coated ?
What kind of Parylene variants did you coat ?
Nelson
Hello Prof.Nirmala S.V.S.G,
Thank you so much for your share.
I am checking on these.
I was asked by one client for the test procedure of parylene coated PCB from SULFUR attack. Is it any professional method or standard to perform this precisely and quantified ? Thank You !
31 December 2016 6,694 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
I did PR spin coating on trench structure. I used AZ P4620 PR and the thickness or PR is around 11um. The substrate is Si. And my trench structure depth is 141um(negative way). Even though I...
08 August 2024 2,298 0 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,176 0 View
What is the most suitable experimental setting to understand the consequences of a particular gene: (1) targeted degradation of the specific transcription factor (TF) of the gene, followed by...
04 August 2024 6,265 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
I am trying to coat my micelles and PLGA based nanoparticles with cell membrane using an Avanti mini extruder according to literature . I use 200nm membrane but my particles end up to be 400nm And...
30 July 2024 3,294 3 View