The sample drop cast on IDT.
Use a low power oxygen plasma,Make sure that the power is low enough as not to heat up the gold electrodes too much or use acetone which is economical and it just takes few minutes.
Good Luck
You can use a variety of solvents if the adhesion layer between the glass and gold electrode is titanium.
the adhesion layer between the glass and gold electrode is titanium. what solvent can be used?
we usually use alcohol.
04 May 2015 7,613 3 View
the graphene has very low weight and cant disperse in water.
01 February 2015 5,522 1 View
and if the synthesized material remain in autoclave for one day is it result in rise of nanoparticles.
31 December 2014 6,627 6 View
How can we synthesize pd doped sno2 nanoparticles by hydrothermal method?
31 December 2014 775 4 View
31 December 2014 498 6 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
I have several question regarding the MOR; hope anyone help me better understand. 1- in CV using (KOH+MEOH) what is the indication of absence of the redox peaks? shouldn't they exist as a sign...
28 February 2021 4,851 8 View
What could be the reason of moisture at the sides of Vial when I am preparing my polmyer+DMSO solution for membrane fabrication? What etiquettes I am possibly missing here?
28 February 2021 6,516 5 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
I notice that upon washing and air-drying of my RGO/SPCE surface and characterizing again via DPV, the current response towards ferricyanide probe significantly decreases. My worry is that the...
22 February 2021 5,324 3 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View
One of my colleagues said, "the impedance you can measure with the three electrodes and with the specific sequence varying the frequency" Is it possible to configure the potenciostat without the...
21 February 2021 418 2 View