When I run my confirmatory factor analysis model in amos one of the error term has a negative variance.Is this a heywood case?
Ceren,
this does sound like a Heywood case.
Aside from checking if there is any accidental misspecification in the model, your can try providing starting values for estimation. I am not sure if this is possible in AMOS, however.
hello, I want to run a MIMIC model in AMOS, is there a ideal number of cause indicators? Thanks on advance,
08 September 2019 8,747 10 View
Hello, My friend created a hypothesis "Is x (variable) is significant?". I found this hypothesis weird:) Anyway, he insists on testing this. I calculated the mean of the scale (x) on SPSS. Is...
07 August 2019 6,930 6 View
How can we interpret negative factor loading? In explanatory factor analysis, how should us interpret negative factor loading? Should we consider absolute value?
31 December 2018 6,718 1 View
Hello, I am trying to run CFA for likert construct? But linearity assumpition is violated. I do not have the oppurtunity to lessen the number of items but there are a lot of items which do not...
31 December 2018 944 0 View
In explanatory factor analysis, I have an item loaded positive in one factor and loaded negative in an other factor, there is a difference less than 0,1 between the two in absoulte terms? Should I...
11 December 2018 6,825 1 View
In structural equation modeling, ECVI is an index that can be achieved in an other sample. But formulation of ECVI does not explain how this works?
11 December 2018 7,076 3 View
In reflective models, should regression coefficients between latent and two indicators have same sign?
10 November 2018 3,027 4 View
Is it necessary to test the significance of marker indicator in SEM? I have a SEM model in which latents have two indicators. I estimated hybrid model using one step approach. When I release...
10 November 2018 4,794 0 View
10 November 2018 1,113 3 View
In my structural equation model, I have a an observed egzogenous variable, according to modification indices, can i link it to an indicator of endogenous latent? Thanks in advance
10 November 2018 6,790 7 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
I have tried to download the 64-bit version of MGLtools however, as many times as I have downloaded and uninstall the programs, an error arises that the app needs to be updated. Thank you.
03 March 2021 5,997 2 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
Hi everyone, I am conducting research for my Master's thesis. I am using PROCESS by Johnson-Neyman to analyze my Moderator model. I test the relationship between Public Service Motivation and...
03 March 2021 2,350 2 View
I have conducted and published a systematic review and meta-analysis research with the topic related to public health and health pomotion (protocol was registed in PROSPERO). Now we want to...
03 March 2021 8,920 3 View
dear community, my model is based feature extraction from non stationary signals using discrete Wavelet Transform and then using statistical features then machine learning classifiers in order to...
03 March 2021 6,994 5 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View