Does anyone know the method of changing the as-welded columnar austenite microstructure into equiaxed austenite microstructure in the weld metal of the austenitic steel? Thank you.
This figure indicates the as-welded columnar austenite microstructure.
Dear,
Did you try heat treatment, put material at temp. high then austenitisation temp.?
Weld metal is cast microstructure.
Heat treatment at certain temperatures (Normalising ~ 1000°C) for several hours should get rid of the as welded microstructure.
Dear Harald Rojacz. The weld metal is the full austensitic microstructure, how can we conduct the normalising treatment?
How could I get the P-value from the mean, SEM, and n of different groups in the t-test without the original data? For detail, I would like to know the P-value between BMP-2: 50ng/ml group and the...
06 February 2021 6,539 4 View
Hi guys I'm out of ideas here please help! I've never had consistent problem like this doing westerns before and I can't figure it out. The condition used: - First 4 lanes have 50ug protein in...
04 February 2021 2,297 3 View
I am searching for miRNA repeats put between WPRE and 3'LTR of my lentivirus, in order to enhance the specificity of transgene expression in human neuron cells. But if clinically translation of...
26 December 2020 9,921 2 View
Recently, I got a concept that is contrary to my understanding from two papers. It can be described as follows, in brief: There are two catalysts for the same reaction, on the catalyst with higher...
09 December 2020 2,406 28 View
Recently I started to use XRD to study the structure of some molecular sieves. My powder sample was prepared by grinding in a mortar, drying in an oven, and loading on the sample holder. However,...
03 December 2020 7,504 8 View
I have installed the software BRUKER Flexanalysis 3.4 on my computer successfully. But when I tried to import the MS data produced by BRUKER MALDI-TOF-MS, I met with an error described in the...
10 November 2020 8,205 1 View
Hi, As described, recently we found a gene was silenced in various tumor, and its promoter was alwasy hypermethlated. When using certain treatment to induce the gene expression, we found its...
04 November 2020 7,054 3 View
Hello, I'm working with immortalized HUVECs low and I'm trying to study their exosomal RNA contents. Could anyone recommend an effective kit to isolate exosomes from cell culture supernatant?...
31 October 2020 4,252 5 View
We need to collect CSF samples repeatedly from the 4th or lateral ventricle of rats. Does anyone know of a protocol for implanting a cannula to be able to do this? Or even a protocol for this...
26 October 2020 5,804 3 View
I am analyzing the tissue damage to the mouse cornea tissue after incubated a kind of medium. The protocol is 1) mouse cornea was incubated in the medium for one day 2) embedding the cornea with...
21 October 2020 7,568 5 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello everyone. Given microstructure image belongs to a 12% ledeburitic cold work tool steel (annealed and tempered). The sample was etched with picral (100 mL ethanol and 4 g picric acid). I...
02 March 2021 4,119 3 View
It is oftentimes said to be a distinctive metallographic trait that differentiates a fully austenitic and a fully felly ferritic steel without etching that might distinguish between two. Why...
02 March 2021 728 2 View
As I was tweaking step-by-step OpenCalphad6 Macros step1.ocm involving phase and thermal property calculation of a High-speed steel, I could not incorporate more than 6 elements in the steel...
01 March 2021 8,840 1 View
I have a structure that employs d-ring swiveling tie-downs that corrode during use and become "frozen". I have sample swivel assemblies that I wish to corrode to see if I can free them using one...
01 March 2021 3,739 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
My main concern is that the metal powders should not weld to the mold surface and I should easily be able to eject out the pressed samples. I am looking for alternative for graphite moulds. The...
22 February 2021 2,965 4 View
Dear all, If steel jacketing is used to retrofit a reinforced-concrete (RC) column, can we use it to improve flexural strength? I understand that we leave gaps between the ends of the jacket and...
22 February 2021 1,906 5 View
Hi all, Does SeismoStruct support modeling rectangular RC columns retrofitted with steel jackets (e.g. rectangular, elliptical) ? Any suggestions for other software (apart from...
20 February 2021 4,521 1 View
How do the thermal conductivity, specific heat capacity, plastic strain, critical compressive displacement, and thermal expansion of both hot-rolled steel and concrete change after cooling based...
15 February 2021 1,385 5 View