Dear all, as luck would have it, I reached for my PureLink PCR Micro kit and the wash buffer totally evaporated. Does anyone know the composition of the wash buffer in the PureLink PCR Micro kit? I assume that it's mostly ethanol, maybe 90% ethanol?
Before beginning, prepare the Wash Buffer (W1) with 100% ethanol as follows: For K310050 (50 preps):
1. Add 32 ml 100% ethanol to the Wash Buffer.
2. Check the box on the Wash Buffer label to indicate that ethanol was added.
3. Store the Wash Buffer with ethanol at room temperature.
For K310250 (250 preps):
1. Add 160 ml 100% ethanol to the Wash Buffer.
I'm cloning a fragment of 3200 nts into plasmid. The cloning was successful, however, 02 amino acids were mutated. Now I want to fix these 02 aa by site-directed mutagenesis technique using...
08 August 2024 4,645 2 View
After performing symmetric PCR, PCR purification was performed. Afterwards, asymmetric PCR was performed using the PCR purification product as a template, but no ssDNA band was confirmed in the...
08 August 2024 1,668 3 View
Does anyone tried to do nucleofection with AMAXA by Lonza with lower than recommended amount of buffer in the cuvettes (100 ul)?
07 August 2024 4,616 0 View
Currently, when I run SDS-PAGE, I don't see any bands at all, even though I used the same material just a day ago and it worked fine.... In our lab, we dilute the 10X running buffer to 1X and...
06 August 2024 5,373 2 View
i have sorted anti-NP specific plasma cells from bone marrow of C57BL/6 mice at certain times after immunization with variable counts and isolated total RNA using TRIZOL method for RT-PCR using...
05 August 2024 8,835 1 View
A Markov-like Model for Patient Progression" Markov Chain Monte Carlo (MCMC) Markov Chain Monte Carlo (MCMC) is a powerful computational technique used to draw samples from a probability...
05 August 2024 10,079 0 View
I want to introduce a point mutation (change in one nucleotide) into my gene of interest (DNA binding domain) I have designed primers as recommended on the Data sheet of the kit : -Both primers...
05 August 2024 9,059 3 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
I am performing ligation of the plasmid and a target gene. The steps I have taken are: 1. Double digestion of the plasmid and target gene 2. Ligation of the plasmid with the target gene 3....
05 August 2024 2,570 3 View
I am having an issue with my gel image where my PCR product is not appearing very bright on the gel. When I perform gel extraction, the A260/280 purity value is very low. I used the Qiagen gel...
05 August 2024 9,798 3 View