Hello,
I have been trying to quantify S-adenosylmethionine (SAM) in NIH3T3 fibroblast using HPLC-MSMS but after several unsuccessful attempts I have try with some other technique. Any suggestions?
Thank you
Instead of using HPLC MS/MS u can use RP-HPLC ........................it is easier compared to the last.
I agree with Ahmed. Use 210 nm UV-wavelength and start from 5% to 90% AcN in 15min, Column: a good C18, f.e. Acquity BEH C18 50x2.1mm, 1.7µm (Waters)
Flow: 0.5 mL/min, Temperature: 30°C, make sure to repeat the gradient runs at least 2-3 times until you have reproducible data.
03 March 2021 8,272 1 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
Hi all, I am validating a polyclonal antibody raised against human ANT4, through WB and ICC. In most of my controls, the antibody shows very little off-target binding, but when I pre-incubate the...
03 March 2021 5,999 3 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...
02 March 2021 1,408 1 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
(This statement is from wikipedia, BTW). What is so special about metallic bond that is limiting high-P low-T state of a matter (as long as individual atoms exist, not white dwarf of neutron star...
02 March 2021 3,309 2 View
I need to prepare a solution of Napabucasin (inhibitor of cancer cell stemness) in dichloromethane. The drug is expensive, so maybe somebody already tried to do it. If it is soluble, what is the...
02 March 2021 9,945 3 View
I took measurements of different concentrations of 15 nm and 5 nm Au nano particle solutions. I'm trying to determine which concentration I measured gives the best reading overall. I also...
02 March 2021 7,626 1 View
im working now on TPV solar cells and metamaterials and i realy need our help in CST microwave i have a tpv cell simulation and i want to extract particullarly the absorbtion of only the active...
02 March 2021 2,246 2 View
Hello! I'll do a size exclusion chromatography, but I only have an open column, and I'll perform the peptide extraction from yeast, using buffer lysis (sodium phosphate 50 mM/NaCl 30 mM/DNAse and...
01 March 2021 2,215 2 View