The band gap for SnO2 based nanomaterial reduces with increase in Cu dopant but the crystallite size reduces with doping. What can be the possible reason? Pls guide
Dear Researchers, I have my samples SnO2 doped with with Cu (1, 2, & 4%). The peak intensity reduces in XRD for 1 and 2%. However, for 4% additional peaks appears which I believe is due to...
05 June 2019 4,917 3 View
Dear Researchers, Since CNT is not soluble in standard solvents like DI water, ethanol etc, how do I make a doping/composite of CNT and metal oxide. Your suggestions will be highly appreciated....
05 June 2019 6,506 2 View
I have quantum dots dispersed a solvent. If I am considering 2 ml of the solvent, then how do I find out how much is the amount of sample in that solvent? I tried drying the sample to obtain...
03 April 2019 4,440 8 View
Some literature and RG search mentions a acid solution for dissolving Co3O4 and NiO. Also, for Co3O4 I tried a basic medium of pH 10, but was unable to dissolve. I am not sure incase I am using...
10 November 2018 4,432 0 View
Dear Sir/Mam, Considering the scale, we measure the distance between the centre and the bright spot of the diffraction pattern. This should tally with the reciprocal of the d-spacing and the...
07 August 2018 3,629 2 View
Kindly let me know the details along with an image of a high temperature hydrothermal reactor operating at 400c to 500c. Thanks and regards
06 July 2018 5,870 3 View
Dear Sir/Mam, I have synthesized some quantum dots suspended in solvent (DI water) . I am interested in finding the size of those dots. One way would be offcourse HRTEM. But I am interested in...
05 June 2018 8,839 3 View
I am interested in synthesizing Graphene Oxide but not by Hummers method. If any one can suggest from his/her expertise. Also, does other method or even Hummer method ensure a good quality. Also...
05 June 2018 3,065 0 View
Dear Sir/Mam/Colleague, What kind of Screen Printers do I use to deposit thin films? If possible provide me with a link of the description of the instrument. Also, what will be the approximate...
09 October 2017 9,239 0 View
I worked on metal oxides and its application for gas sensors. Now I intend to write a project, and found Bio-sensors (using metal oxide) as a very interesting project. My doubt lies, whether the...
07 August 2017 5,615 0 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
We have observed that tube to tube sheet joint leaked in our boiler and needs to overcome same by knowing the root cause.
08 August 2024 3,161 0 View
I need to do some experiment with it in liquid form.
07 August 2024 613 3 View
All plants are green but some of these plants becomes yellow. I did not found any reason. Please help me to find out the real problem.
01 August 2024 589 4 View
Dear all! Oxygen vacancies do raise negatively the Fermi level by increasing the negative charge in the semiconductor crystal structure. In the case of n-type semiconductors, I wonder if this...
30 July 2024 8,339 2 View
Hey All! I am wondering what might be wrong with my band structure. I did the calculations using VASP and plotted the results using Origin. Although I have tried changing various input...
25 July 2024 2,920 11 View
It is being seen that Editors of some reputed Journals are putting on hold the manuscripts and not updating review states even passing more than six months from submission. Researchers are...
24 July 2024 8,596 2 View
I want to calculate the spin texture for the electronic band structure obtained from SOC calculation. Is there any way for calculation of spin texture using quantum espresso??
19 July 2024 8,571 1 View
Suppose a material "A" has both tetrahedral and octahedral sites and we are doping another material "B" - usually an ion into it. How can we detect if the dopant has occupied the octahedral site...
17 July 2024 4,299 4 View
Our lab has some radioactive cell samples that need to be kept frozen for at least 30 days before flow analysis. For some reason, the samples stored in liquid nitrogen did not perform as well as...
15 July 2024 9,975 1 View