I am trying to compare CV data. If anyone can provide CV of pure Au electrode as well as PANI@Au electrode would be great.
strong Au peak near -0,9 V
If you can add more details like an electrolyte, pH then it will be easy to suggest something.
However, you can go through this article especially Fig.2. pure gold is also similar to it
Thank you António Maximiano Fernandes and Bhushan Patil
I have to do morphology characterization of the modified working electrode. At present, I only have CV instrument with me. Can anyone help if I can do electrochemical surface characterization,...
05 June 2018 6,921 5 View
In many research papers for detection of glucose unit of LOD is reported as microM whereas concentration of analyte used in mM. Please if anyone can justify.
11 December 2017 9,351 3 View
Hi, I am trying to make 1000 mL of 2mM PVF solution. Can anyone suggest do I have to consider the mol wt of VF for determining the wight of PVF to be used.
10 November 2017 1,243 3 View
Hi, I am looking forward to calculate area of my Pt electrode which I have modified and used in 3 electrode system for glucose solution in NaOH estimation. What I did is As per Randles–Sevcik...
10 November 2017 3,973 8 View
Hi I have to apply constant potential of −0.50 V for 5 min for a 3-electrode system in HAuCl4 solution. I am using Electrochemical workstation. Which technique should I use? Is it, Normal Pulse...
10 November 2017 6,357 13 View
I need to calculate sensitivity of modified Pt electrode. For this, I need slope (which I got from calibration curve) and area. Can anyone please tell, how to calculate area to be used here.
09 October 2017 9,071 6 View
Hi, I have polymer film modified Pt electrode. How can I calculate the thickness of this polymeric film using CV? Thanks in adavance
09 October 2017 4,270 2 View
I am trying to do barometric sensing of my modified electrode. Can anyone please let me know the technique which I should use?
08 September 2017 3,355 6 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View
I have attached the charging curve from the battery tester for review. I need help on what is happening
21 July 2024 6,898 2 View
I want to know that n-doped side of solar cell is connected with positive or negative electrode.
20 July 2024 1,348 2 View