I am trying to compare CV data. If anyone can provide CV of pure Au electrode as well as PANI@Au electrode would be great.
strong Au peak near -0,9 V
If you can add more details like an electrolyte, pH then it will be easy to suggest something.
However, you can go through this article especially Fig.2. pure gold is also similar to it
Thank you António Maximiano Fernandes and Bhushan Patil
I have to do morphology characterization of the modified working electrode. At present, I only have CV instrument with me. Can anyone help if I can do electrochemical surface characterization,...
05 June 2018 6,693 5 View
In many research papers for detection of glucose unit of LOD is reported as microM whereas concentration of analyte used in mM. Please if anyone can justify.
11 December 2017 9,114 3 View
Hi, I am trying to make 1000 mL of 2mM PVF solution. Can anyone suggest do I have to consider the mol wt of VF for determining the wight of PVF to be used.
10 November 2017 1,008 3 View
10 November 2017 3,641 8 View
10 November 2017 6,087 13 View
I need to calculate sensitivity of modified Pt electrode. For this, I need slope (which I got from calibration curve) and area. Can anyone please tell, how to calculate area to be used here.
09 October 2017 8,831 6 View
Hi, I have polymer film modified Pt electrode. How can I calculate the thickness of this polymeric film using CV? Thanks in adavance
09 October 2017 4,016 2 View
08 September 2017 3,114 6 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View
One of my colleagues said, "the impedance you can measure with the three electrodes and with the specific sequence varying the frequency" Is it possible to configure the potenciostat without the...
21 February 2021 418 2 View
Hello everyone Do you have any information about this error 'The experiment was stopped by a potential overload on Vs (auxiliary electrode)' in Origamaster software? I tried everything possible,...
19 February 2021 3,152 7 View
The experiment is really simple. When I do a bulk electrolysis with 1% TFAA (ACN solution) to get dihydrogen, what is going to be oxidized? (working electrode graphit, counter electrode platinum,...
18 February 2021 4,430 1 View
I am working on cathode material. I have made different Li-ion coin cell against Li metal using commercial available cathode materials such as LCO,LMO, LFP and NMC and also with the lab...
18 February 2021 1,450 3 View