We want to perform WB with the secretome of an endothelial cell line, but we have very little sample volume and we cannot spend it testing the antibody. Could you suggest a good antibody with its best working dilution?
Annexin1 Ab from CellSignaling (3299S) with 1:700-1000 dilution.
Thank you Andrei, I think we will try it.
Best Regards from Barcelona
Annexin A1 from Novus Biologicals
1:500 - 1:2000 diluition
http://www.novusbio.com/Annexin-A1-Antibody-2F1_NBP2-23485.html#
We are trying to isolate CD63+ exosomes in order to characterize them by electronic microscopy, Nanosight and ultimately by proteomics/transcriptomics. To isolate them we use the “Total Exosome...
10 November 2016 6,925 6 View
We want to separate proteins of 2-20 KDa in tricine gels, stain them with coomassie and cut the bands of interest based on their molecular weight.
04 May 2014 3,763 2 View
We want to analyse Citrate synthase in an endothelial cell line and have a reduced sample volume so we cannot lose it performing tests. Could you suggest a good antibody and its best working...
31 December 2013 3,511 2 View
In our SILAC experiment we analyzed supernatants from cell cultures. It seems that treated cells secrete more protein than control cells (more or less 3 fold, as checked in many other cultures we...
11 December 2013 8,002 1 View
I got these smeared bands quite often lately. We typically run the gel at 140V with a 10-12% gel and do a wet transfer at 220 mA for 1.5 hr in cold room. We also noticed some dirty spots/dots (see...
10 August 2024 7,480 3 View
Can anyone share any reference that gives mouse specific CD3 antibody sequence. I have been searching for this since few days and no luck. Thank you very much
08 August 2024 9,157 4 View
I'm working on selecting antibodies against a recombinant protein that has a His-tag. My idea is to first bind the recombinant protein to a HisTRAP column and then use this column for an affinity...
07 August 2024 505 3 View
Hi, I know that low molecular weight (MW) molecules generally tend to have higher mobility, while high molecular weight molecules tend to have lower mobility. However, in my experimental...
06 August 2024 1,495 2 View
After immunohistochemistry of previously fixed in PFA and EtOH and then frozen 20 μm sections of zebrafish brain, DAPI staining is very weak (right) compared to the same sections stained without...
05 August 2024 9,637 2 View
Brain and body mass together are positively correlated with lifespan (Hofman 1993). The duration of neural development is one of the best predictors of brain size, and conception is the best...
05 August 2024 6,247 3 View
kindly reply me. Thanking you in advance.
05 August 2024 7,727 4 View
Is it possible to conduct a molecular dynamics simulation to see the effects of a specific carbohydrate on the structure of lipids (e.g., micelle structure)? I am a beginner in this field and plan...
03 August 2024 3,371 3 View
I am using a windows system, what software I should use for hydration shell analysis with molecular dynamics?
02 August 2024 3,143 4 View
Molecular docking software/ websites?
02 August 2024 8,704 7 View