I want a microbalance for my trough and I want to know the minimum level of accuracy considering its suitable price.
I have read in the following manual that the balance should be capable of measuring accuracies of at least 0.1mg. is it true?
You may use an analytical balance 0.1mg accuracy. Better accuracy (1 microgram) is usual to microbalances, but the price is much higher.
http://www.mt.com/gb/en/home/products/Laboratory_Weighing_Solutions/Micro_Ultra_Balances.html
https://www.sartorius.com/sartorius/en/EUR/products/laboratory/laboratory-balances/analytical-balances
Can you help me please, How can I make sure about the formation J-aggregation of (PIC) dye on solid substrate by Langmuir-Blodgett technique? Is there any other way except uv-visible absorption...
11 December 2017 8,459 7 View
07 August 2017 1,172 2 View
I wan to create J-aggregation of pseudoisocyanine dye by Langmuir-Blodgett technique and I am going to use Arachidic acid to do this. Now my question is "how much is the area per molecule for...
07 August 2017 4,216 2 View
For creating J-aggregation of cyanine dyes such as pseudoisocyanine dye by Langmuir-Blodgett trough, which one in better? 1: dissolving this dye and Arachidic acid in chloroform/methanol mixture,...
07 August 2017 1,446 4 View
I have polystyrene spheres with diameter of 800nm that are suspended in water, can I create carboxylate modified polystyrene with them?
04 May 2017 9,027 5 View
Which dyes can easily form J-aggregate by L-B method(on a glass substrate)? How about Merocyanine dye?
01 February 2017 6,047 4 View
In generals, What methods are there to create a J-aggregation of dyes (for example Rhodamine) on a glass substrate? and how can I use L-B technique for that?
01 February 2017 8,613 2 View
31 December 2016 2,187 6 View
Excessive rotation of nodes in node set ErrNodeExcessRotation-Step1
17 August 2021 0 0 View
20 June 2021 0 0 View
The role of climate change influencing the human behavior as well as economics interest
01 June 2021 0 0 View
effect of double bond on the flexibility of polymers
07 April 2021 0 0 View
--> FOAM FATAL ERROR: Maximum number of iterations exceeded From function Foam::scalar Foam::species::thermo::T(Foam::scalar, Foam::scalar, Foam::scalar, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar) const) const [with Thermo = Foam::hConstThermo >; Type = Foam::sensibleEnthalpy; Foam::scalar = double; Foam::species::thermo = Foam::species::thermo >, Foam::sensibleEnthalpy>] in file /home/ubuntu/OpenFOAM/OpenFOAM-4.1/src/thermophysicalModels/specie/lnInclude/thermoI.H at line 66. FOAM aborting #0 Foam::error::printStack(Foam::Ostream&) at ??:? #1 Foam::error::abort() at ??:? #2 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::calculate() at ??:? #3 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::correct() at ??:? #4 ? at ??:? #5 __libc_start_main in "/lib/x86_64-linux-gnu/libc.so.6" #6 ? at ??:?
24 March 2021 0 0 View
I am writing to request some information for making polymer color flakes. I would appreciate the help.
17 March 2021 0 0 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello, good day! I am trying to simulate similar bimorph piezoelectric harvester with below commands. However, the output power doesn't change with resistor value. Please help to find the reason. ET,10,CIRCU94,0 !SET UP RESISTOR R,1,100000 !RESISTANCE VALUE TYPE,10 !SET ELEMENT TYPE E,1,2 !CREATE RESISTOR BETWEEN NODES 1 AND 2 Thanks in advance Regards,
02 March 2021 0 0 View