Hi,

We have encountered something strange. Our group is purifying an N-tagged 6xhis protein with Talon 5ml prepackaged column. When we first tried with 2ml sample volume, everything worked great. Then we tried 8ml sample volume (4x), and we expected a 4 fold increase in protein yield. Indeed the result was as what we thought.

However, when we apply 15ml sample volume, the protein yield is about the same as what we get with 8ml sample volume... It was about 1.5mg of protein, Theoretically, Talon column is able to bind 20mg protein per ml resin, so there is no way we were reaching that limit.

Our binding buffer: 50mM PBS, 300mM NaCl, which was used as cell lysis buffer with additional PMSF.

Wash buffer: 50mM PBS, 300mM NaCl, 5mM Imidazole

Elution buffer: 50mM PBS, 300mM NaCl, 150mM Imidazole

No EDTA was involved at all. And we don't think it's the buffer issue otherwise it would not work with 2ml and 8ml sample volume, right?

Please help! Thank you so much!

PS we really don't want to purify under denatured condition, so let's just skip the detergent part! :)