12 Questions 9 Answers 0 Followers
Questions related from Craig Mcbeth
Hello all, I have used HEPES in the past to maintain my cells outside of CO2 incubators for extended periods of time, however some of my recent work would best be performed if the bicarbonate...
11 November 2019 1,895 3 View
Hey all, I have used a standard Ag/AgCl electrode for a while now but I've just moved institutions and a lab member is stating the electrolyte is not required for aqueous voltammetric analysis,...
01 January 2019 6,587 5 View
Hello all, I'm looking to improve the sensitivity of a mediated carbon electrode. The mediating compound is being added via solvent casting post electrode printing, so any additional treatment/...
04 April 2018 1,139 4 View
Hello all, I have been trying to modify a plain printed carbon electrode with cobalt(II) phthalocyanine and I have found my CV does not look like any of the CVs in literature. I have attached a...
02 February 2018 1,900 3 View
Hello all, I've been trying for a while now to crosslink dopamine to chitosan using various means, more recently I have been using glutaraldehyde. My electrode is made in house using an ink from...
12 December 2017 4,447 1 View
Hello all, I've been trying to functionalise some CNTs with a carboxylic acid side-chain but I've been having difficulty with my end-product, resulting in negligible yield. My current protocol is...
03 March 2017 4,072 6 View
Hello all, For the past week I have been working on a new electrode, the process however uses a double solvent cast in the construction of the electrode. Initially a layer of CNT + Nafion in...
02 February 2017 6,374 2 View
I have been trying to measure extracellular hydrogen peroxide in basic MEM using electrochemical means. I have been inducing a mimetic state of hypoxia using cobalt chloride hexahydrate and have...
08 August 2016 975 2 View
Hello all, I'm trying to find some literature on the electrochemical quantification of certain metabolites, amino acids or anything really, in cell culture media e.g. DMEM, EMEM, RPMI etc. Ideally...
04 April 2016 3,348 4 View
Hello everyone, I'm rather new to electrochemistry on the whole so I'm struggling to trouble shoot this issue. I have been experiencing potential issues with the data I have received from my CV...
04 April 2016 8,078 5 View
Hello all, I've been trying to perform a Nitrite/ Griess assay on isolated cell media but no detectable traces of Nitrite is present. The media itself is phenol red-free MEM supplemented with...
05 May 2015 1,611 5 View
I've been searching for any studies relating to the study of cell culture supernatant and the potential biomarkers that may present within unprocessed media. I keep running into paywalls, dead...
10 October 2014 9,528 6 View