My catalyst has both Fe and Fe3O4. I am wondering whether the IR peaks of C2H4 molecules adsorbed on Fe and Fe3O4 sites will negatively or positively moving. If yes, is it distinguishable or not? Thanks
When I conducted the degassing experiment using decompression under anaerobic condition(and I used ferrous based chelating agent), the oxidized ferric were observerd. So, could you tell me the...
03 March 2021 4,892 5 View
Hi, I am after the reference below, my library says it cannot obtain a copy either locally or internationally, any help appreciated! Chris Wang ZM, Heshka S, Wielopolski L, Pi-Sunyer FX, Pierson...
03 March 2021 6,193 1 View
We have synthesized various metal complexes with different environment around the metals. Now to see the application of synthesized complexes we need this study also. we are also interested in...
01 March 2021 1,899 2 View
Hello everyone. I have conducted the research on post harvest longevity of tomato crop using plastic packaging and different doses of chemicals as two different factors. The design of experiment I...
28 February 2021 8,189 3 View
The antimicrobial effect of local anesthetics has been known for more than 50 years, but it still seems to have an unclear mechanism of action. which bacteria? which concentration? etc etc. ....
27 February 2021 4,450 2 View
24 February 2021 5,378 1 View
In the PVD of TiN thin films (~100A), I've found the resistivity of the TiN films dropped from ~100 to 60um*cm with N2 flow increasing up to the metallic mode ending point; then the resistivity...
21 February 2021 1,864 2 View
Hello. I want to isotopically label the my protein, and I express it in BL21 RIPL using M9 minimal media. It grows extremely slow. I inoculate the colony from a fresh M9 plate into 5ml M9 medium...
17 February 2021 2,852 2 View
Dear colleagues We are exploring possible data collection methods for environment and behavior research in the context of architectural environments. Have you conducted any Post Occupancy...
16 February 2021 2,575 4 View
To maintain the proper crop plan most of the times there is not enough time to make the field ready for the next crop. In this particular context , can bio-decompser be a solution? What about...
16 February 2021 7,068 24 View
The figure shows DSC cooling (blue) and 2nd heating (green) curves (step: 10 K/min) for a commercial sample supplied as Atactic Polypropylene (APP). The heating curve illustrates two major...
03 March 2021 5,857 3 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello Everyone. Currently I am working to characterize macrophages in the myocardium after ischemia-reperfusion injury in rats. Due to the low total cell number isolated from rat hearts I can...
01 March 2021 3,867 3 View
I'm looking at the aggregation of my protein sample using DLS. Unfortunately, my buffer (20mM HEPES) also results in a set of peaks. These are at approximately 1 and 1000 d.nm. The lowest peak...
01 March 2021 9,015 2 View
I have always been interested in geology and wondered about how unique structures of materials behave in different circumstances. I stumbled upon Olivine, the magnesium iron silicate, and heard...
28 February 2021 7,330 4 View
i have recorded raman spectra of strontium oxide thin film. the spectra were recorded in the range 400 to 4000 cm-1. i have reference to peaks upto 1000cm-1. but i couldn't find literature for...
26 February 2021 2,499 1 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I have several Raman spectra with very distinct peaks at certain wavenumbers, such as 277, 359, 466, 583, 623, 686, and 795cm-1. How can I identify them to what compound(s)? The RRUFF and others...
24 February 2021 363 3 View
Hi all, I am doing a genescan analysis for a deleted exon in the patient sample. The amplified region is 215 bp. In the patient sample because of homozygous deletion, no peak is observed while in...
23 February 2021 5,645 1 View