Abaqus user
How can I calculate IC50 in the DPPH test using graph pad prism software? or suggest a manual method and other software to calculate the IC50 value.
06 August 2024 8,848 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
Good day! I am currently testing my sample for MIC, may you help me how to interpret the results at OD630? how would I know if there is growth or not based on the values given by the microplate...
01 June 2024 7,920 3 View
It´s known that generation distributed especially from solar energy power plants has increased sharply in the last ten years into distribution systems around the cities. Although it brings many...
05 April 2024 5,040 0 View
Most of the research articles mentioned biosensor stabilty study conducted for 21 days Or a month. Is it a standard period of time to test the working stabilty of a biosensor?
19 March 2024 7,822 1 View
We recently ran the NanoString nCounter Fibrosis V2 panel and results were unexpected. The submitted RNA samples were validated by running a single gene in an in-house qPCR. Within each treatment...
18 March 2024 2,058 0 View
There is no available sca here in the PH, and we need to isolate Actinomycetes. Thank you in advance!
20 January 2024 4,713 2 View
Hello Everyone, I am currently using SolidWorks Simulia for transient thermal simulations. There is a solid object that needs to be heated with a hot liquid. Initial condition of the solid is...
03 January 2024 6,100 0 View
Currently, I am doing a cyclic study (charge-rest-discharge-rest) of a LFP cell. During the study, I have observed that the amount of energy pushed to the cell or drawn from the cell is reducing...
03 January 2024 9,826 0 View
I am doing Bader charge analysis in VASP. My Bader charge simulation died and received the following error. Any suggestion will be highly appreciated. *Error in adding charge density: can’t use...
03 September 2023 6,463 2 View
I have input a moment load in module load Abaqus, i put my moment load on the node surface (using reference point). I have define moment in history output and make a set for moment too. But the...
08 August 2024 4,831 4 View
I have modelled a steel structure using beam elements in Abaqus and attached to this structure reinforced concrete slab. The analysis that I am making is heat transfer of the structure. The...
07 August 2024 1,028 0 View
I am working on Abaqus/Explicit(Quasistatic ) for the deformation of the auxetic structure model. Please explain how the plastic input value should be considered from the true stress-strain curve...
05 August 2024 454 3 View
I want to know more about REE deposits.
03 August 2024 6,930 2 View
31 July 2024 7,366 1 View
Hello, colleagues. Recently, I have been working on a metal processing simulation with my UMAT in Abaqus. I have outlined the corresponding simulation, but I keep encountering issues that cause...
30 July 2024 7,062 1 View
I am trying to run a restart analysis, which imports deformed configurations of parts from a generated ODB file. It runs fine in Windows OS but when I try to run it in Linux OS, it is giving some...
29 July 2024 9,572 3 View
Sure, here is the translation: I have a 3D orthogonal woven composite structure where warp, weft, and binder yarns are oriented in three directions. After modeling these yarns and the matrix in...
28 July 2024 8,169 0 View
hi, I am doing a risk analysis of a cylindrical fuselage with windows. I have applied contact interactions between the different parts, and I have applied a unit value load to a reference point,...
20 July 2024 647 2 View
Hi all, I am using the element deletion process based on a Tsai-Wu criterion through a UMAT with a specific State Value controlling the process (DepVar -> Variable number controlling element...
17 July 2024 1,501 1 View