I carried out the CV in 0.5M NaOH with Ag/AgCl electrode. But the result is not as expected. So I switched to other conditions.
I want to know the reason in detail with reactions. Can anyone please?
Ag+ + HO- = AgOH then 2AgOH=Ag2O (black pp.) + H2O
Ag2O blocks the membrane (frit) of your REF electrode. Use a salt bridge (KNO3 sol.).
Can anyone share the PXRD pattern of Quinones? In perticular, I need for Benzoquinone and Hydroquinone.
05 June 2016 2,977 3 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
I imagine the battery drives the graphite into a carbocation, then chloride is oxidized to donate the electron to the carbocation, but what pushes the lost electrons of chloride to be shared...
03 August 2024 5,384 0 View
Regarding a model for simulating battery charge and discharge, what do you consider to be high fidelity? What is the acceptable percentage of error (regardless of the metric)? Could you suggest...
03 August 2024 5,358 0 View
I am an Mphil research student and looking for high impact factor battery related journals to download and read research articles to improve my knowledge and get new ideas in the field of battery...
01 August 2024 6,516 2 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View