What should be the physically acceptable range of active mass of a supercapacitor electrode?
As specific capacitance depends on mass so whether a mass in the range of micro-gram is physically acceptable?
Active mass in the range of microgram is acceptable when your electrode is completely covered by the active material. Nevertheless, the active mass would depend on the area of the electrode also.
Is 5-10 microgram is OK?
Please tell which open source software is best to draw flow charts diagram for research paper.
11 December 2014 3,283 4 View
If I want to measure the capacitance of my thin film, then how should I proceed using the The Metrohm Autolab Instrument?
10 November 2014 7,881 4 View
I have read a few papers where the vacuum filtration is employed to fabricate GO membrane. Here the concentration is an important parameter . I am unable to find any direct relation between...
08 September 2014 6,452 1 View
Minimum thickness of Graphene film to replace ITO.
08 September 2014 10,001 5 View
WS2 has a special property that in bulk form it is an indirect band gap semiconductor where as if we consider monolayer or a few layer then it is direct band gap semiconductor. The room...
08 September 2013 6,606 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View
I have attached the charging curve from the battery tester for review. I need help on what is happening
21 July 2024 6,898 2 View
I want to know that n-doped side of solar cell is connected with positive or negative electrode.
20 July 2024 1,348 2 View