For my experiment I'm required to etch a screen printed Carbon working electrode with 0.1 M NaOH as a first step.
Chronoamperometry at 1500 mV (imposed potential) for 20 s.
Thank you very much Dr. Cornel Radu !
Thank you for this question, was just looking for this info.
Hi, I'm currently looking for KPC-1 (Carbapenem-Hydrolyzing b-lactamase) producing isolates. KPC-1 is basically a Carbapenem Resistant Strain of Klebsiella pneumoniae. Does anyone know of a good...
10 November 2018 7,169 3 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
How do interactions between the biosphere, the carbon cycle, and the water cycle impact global warming and interaction between the atmosphere and the hydrosphere?
09 August 2024 3,291 2 View
Global ‘Weather’ has stopped, as ‘aqua thermionic instituted by the ‘Global thermo atmospherics has instituted global thermodynamics of 120º C + and thus all waters are, or have boiled into a...
06 August 2024 8,716 0 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
The starting material is a finely ground powder. Some particles contain more graphene than others.
30 July 2024 3,978 2 View
I am currently working on modeling FCC catalyst regeneration and have come across a point of uncertainty that I hope you can assist me with. In my previous models, I have utilized lumped kinetics...
30 July 2024 6,137 0 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Hello, I'm trying to measure the conductivity of semiconductor films but since I don't have a commercial four point probe set up I would like to build one on my own in my lab. I have generators,...
30 July 2024 906 2 View