I am observing a different I~V cyclic voltammogram while doing 2 electrode test in electrochemical measurement. I don't understand the reason behind this behavior.
I am obtaining this voltammogram for various oxide based symmetric supercapacitors.
Probably an artefact. The time constant of the system (RC) matches with that of your instrument.
For the synthesis of oxide nanoceramics, to reduce the powder from its higher oxidation state, it is required to be undergone vacuum reduction. What is the mechanism and how to carry out the process?
04 May 2018 4,018 4 View
During synthesis of graphene, how the structural change happens? What exactly the mechanism that is followed here?
05 June 2017 2,669 3 View
The material composition for this purpose.
04 May 2016 9,625 2 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
Is the electropolymerisation of polyaniline coating over stainless steel (SS) via Cyclic voltammetry technique is really adherant? Else how to improve the adhesion of the coating, whether any...
01 March 2021 8,220 2 View
I have several question regarding the MOR; hope anyone help me better understand. 1- in CV using (KOH+MEOH) what is the indication of absence of the redox peaks? shouldn't they exist as a sign...
28 February 2021 4,851 8 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View
One of my colleagues said, "the impedance you can measure with the three electrodes and with the specific sequence varying the frequency" Is it possible to configure the potenciostat without the...
21 February 2021 418 2 View
Hello everyone Do you have any information about this error 'The experiment was stopped by a potential overload on Vs (auxiliary electrode)' in Origamaster software? I tried everything possible,...
19 February 2021 3,152 7 View