I am polymerizing pyrrole on Screen Printed Carbon Electrode, but the trend looks as in picture attached what may be the reason behind this ?
i think this is depending on the polymerization conditions
This would suggest that the electrode area is changing due to the polymerization.
Can you give the continous scan segment number ?
The lowest one is first cycle followed by upper ones. Scan was done in voltage range of 0 t0 0.8 @ 10 mV/S
Kim's reply above is right. The same happens also with metal deposition, i.e. during nucleation.
I am in search of a simple electrochemical method for modification of electrode surface with Fe3O4 and aniline and electrodeposition of AuNPs and/or MWCNT to increase the sensitivity, intended for...
06 July 2016 456 4 View
Does the brightness darkness tell us something about conductivity ? Please provide some references. Book chapter on analyzing SEM Images could be much appreciated.
02 March 2016 6,562 2 View
Can I use NaOH solution to increase the pH of the system to a desired level ? Does NaOH have effect on the sensing property of the electrode ? If I can how can I do it ? If not how would I do it ?
31 December 2015 6,285 10 View
I am using Screen Printed Carbon Electrodes to fabricate Molecularly Imprinted Polypyrrole based sensor for tetracycline detection.
10 November 2015 369 2 View
I would like on work on detection of growth promoters in animal feed using molecularly imprinted polymer technology.
03 April 2015 3,923 4 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,176 0 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Dear All, here is my question: if I have a 15-scans cyclic voltammetry performed with PalmSens, how can I obtain the charge passed during the process? Hopefully avoiding integrations,...
29 July 2024 3,733 5 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View