I need to analyze fibers by x-ray diffraction but the only diffractometer I have available is one designed for single crystal-diffraction.
Hi
You can go with single crystal diffraction. Anyway fibres are almost single crystal materials. You may miss some of the peaks but you can get analyzed
You should tell more on what you actually want to measure. Some instruments with 2D detectors also allow to collect powder diffraction data from "single" crystals.
A Markov-like Model for Patient Progression" Markov Chain Monte Carlo (MCMC) Markov Chain Monte Carlo (MCMC) is a powerful computational technique used to draw samples from a probability...
05 August 2024 10,079 0 View
Hoy la animación se utiliza como una tecnología multimedia con gran potencial educativo, que va mucho más allá de sólo crear figuras, ya que puede promover una mejor comprensión en...
01 August 2024 7,186 0 View
Hi there, My question is: What standard curves should be used while estimating Tot GSH and GSSG by kinetic method using GR enzyme mediated recyling with DTNB chromophore? Actually I am following...
01 August 2024 8,217 1 View
i m interested in pca analysis of c-alpha atoms in gromacs for that i used the following gmx_mpi covar -s mdca.tpr -f mdca.xtc -o eigenvalca.xvg -v eigenvecca.trr -av average.pdb -n index.ndx but...
30 July 2024 1,607 1 View
What exactly is Retrieval Augmented Generation for Large Language Model doing? Isn’t it data engineering?
30 July 2024 7,376 3 View
After a lot of feature engineering for click-through rate modeling, it feels like it's basically the end of iteration? I mean, it's not cost-effective to keep doing it?
29 July 2024 4,955 0 View
Genome-wide association study (GWAS) Continuous traits: eg. Height Discrete traits: eg. Eye color
28 July 2024 286 0 View
all math can be traversed by code? all math can be translate to code?
26 July 2024 9,530 0 View
Hi, Kindly guide me that how many cells of HEC1A & HEC1B Cell lines should I seed for Wound healing assay and which plate type is recommended 6, 12 & 24?. Articles suggested mainly 24...
20 July 2024 4,143 2 View
Hi, everyone This figure depicts a simulation of an electrostatic energy harvesting system in COMSOL Multiphysics software. My question is regarding the relationship between the changes in...
19 July 2024 4,694 4 View
Require for Rietveld refinement in XRD.
08 August 2024 3,081 2 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View
How to calculate the molar proportions of the oxides from the XRF analyses?
02 August 2024 2,565 2 View
I fabricated Ti3C2Tx using concentrated HF 40%, I plot an XRD as attached image below.. please let to know if I obtained it or not.
02 August 2024 6,789 4 View
What information we can get from PXRD analysis other than from SCXRD analysis of a crystal ?
30 July 2024 6,261 4 View
I will be doing an XRD on a sample which is powdered in natured and is a hydrogenated compound. I would like to know how we can understand the individual components and components by using the...
28 July 2024 4,548 2 View
Hi there, I'm new to modelling with comsol. I would like to ask if it is possible for comsol to output linearly polarized (LP) modes? I tried modelling a simple single mode fiber with an enlarged...
23 July 2024 4,019 3 View
I'm working with a hydrogel sample and I'd like to perform XRD analysis. Can anyone offer guidance on preparing the hydrogel for the XRD instrument? Specifically, I'm unsure about the best method...
20 July 2024 3,611 4 View
Can we measure the 2θ variation within a 5-degree range on a Bruker D2 Phaser XRD machine? I have experienced problems with diffraction angles (2θ) below 10 degrees. Is this range within the...
13 July 2024 2,615 4 View