We have synthesized a polymeric coating with pyrene units. It is showing fluorescence in UV region and not showing in visible region.
UV region based fluorescent coatings could be used as inks in anti-counterfiet applications.
Hi, I have a commercial epoxide material. It contains 10 mol% diol impurity in it. If anybody has information about the separation of the diol impurity from epoxide material, please share with me.
11 December 2015 370 8 View
Generally, polyesters which are synthesized by the reaction between diacid and dialcohol, are some sort of yellow or dark colour. Is it possible to stop this discolouration during polyester synthesis?
09 October 2015 7,551 4 View
In general, self-healable coatings are synthesized by incorporating the nano/micro capsules (consist of reactive monomers) into the formulation. I would like to know if there is any coating which...
11 December 2014 6,477 3 View
What is the reason for this quenching ?
08 September 2014 7,845 5 View
Generally metal oxide nanoparticles like ZnO, TiO2, SiO2 etc. have surface hydroxyl groups. what could be the reason and is it possible for them to participate in hydrogen bondings?
08 September 2014 7,485 9 View
If a polymer film is showing high shape recovery property in the tensile mode what could be the expected application?
08 September 2014 5,880 7 View
What are the fluorescence applications of a polymer in the UV region (not in visible region)?
01 February 2014 5,764 1 View
Can ZnO cause fluorescence quenching?
09 October 2013 5,477 1 View
Is there any instrument to determine it?
08 September 2013 7,472 1 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
I am using Rhodamine6G as gain medium and silver nanoparticles as scatterers on a microscope slide and laser input 532 nm comes from above.
09 August 2024 9,894 2 View
How can I measure the thickness of thin film by Uv-Vis?
06 August 2024 7,810 3 View
After immunohistochemistry of previously fixed in PFA and EtOH and then frozen 20 μm sections of zebrafish brain, DAPI staining is very weak (right) compared to the same sections stained without...
05 August 2024 9,637 2 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
Are there any fluorescently labeled anti-Alpaca secondary antibodies raised in Donkey? So far I have only been able to find anti-Alpaca secondaries raised in Goat. Or is this not possible due to...
04 August 2024 4,255 1 View
What is the method for analytically calculating the wear and service life of polymer-polymer sliding pairs?
04 August 2024 1,078 1 View
Hello. I am working on ROS production of two systems: system A is cerium oxide and hydrogen peroxide, system B is cerium oxide nanoparticle, hydrogen peroxide and potassium bromide. I did some...
04 August 2024 5,974 3 View
Why is TLC not a form of partition chromatography and paper chromatography not a form of absorption chromatography?