When testing a biosensor with different concentrations of antigen, it is said that the electrode should be flushed with PBS. Is PBS alone sufficient or the washing protocol with PBS+Tween 20 and PBS should be completed each time?
Our biosensor works acceptably when using serum. However we are reading currents even higher than baseline (DPV in feCN6) when we have switched to plasma. The DPV reading is the same when plasma...
05 June 2019 9,797 8 View
I have the 3D dimensions of my centerlines. I need to calculate the normal vectors at each point in order to draw the surfaces. Can anyone help me?
31 December 2014 5,474 3 View
I have exported the centerline of my vessel and its branches as a matrix in matlab.... Now I want to detect the main vessel and the branches and color them differently ... Any one has an idea?
31 December 2014 5,530 7 View
I have done aorta simulations in Fluent for three meshes. How can we say which one has the better quality for my further tests? The results are nearly the same.
11 December 2014 5,132 6 View
I need a quick step by step guide to perform static and dynamic simulation for blood flow in an artery in Fluent. I am a total novice with the software and the topic, and the user's guide is...
10 November 2014 1,196 11 View
There are several methods that measure the density, diffusion coefficient and velocity of fluorescently labeled macromolecules in cells, but I can't find a way for microfluidics systems.
09 October 2014 2,159 18 View
I want to make a pencil lead electrode. I have used different types HB, 2B, 2H but I haven't recorded a good signal in cyclic voltammetry. Does anyone have any experience?
11 December 2013 6,940 30 View
I want to develop a sensor. I am confused because some sources say I have to add a capture antibody and then a detection antibody. While searching the products I can only find anti-marker Ab and...
10 November 2013 2,753 2 View
I want to explore the long-term effects of incarceration on a youth's developing brain. I also want to explore research that looks critically at incarceration and punitive measures as the primary...
12 August 2024 862 0 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
My name is Apurva Saoji. I am a Ph.D scholar in Computer engineering in India. I am looking for international expert in reviewing my PhD thesis, "Competitive Optimization Techniques to Minimize...
07 August 2024 4,600 2 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
Please go through my Abstract. I can also share a proposed Thesis Outline.
04 August 2024 2,077 0 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
What are the roles of innovation in achieving the Sustainable Development Goals (SDG)?
31 July 2024 3,533 2 View
We are looking for projects for a team of professional developers About us We are a team of experienced developers with over 10 years of experience in various programming fields. Our mission is to...
30 July 2024 8,377 0 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View