9 Questions 21 Answers 0 Followers
Questions related from Patricia Khashayar
Our biosensor works acceptably when using serum. However we are reading currents even higher than baseline (DPV in feCN6) when we have switched to plasma. The DPV reading is the same when plasma...
06 June 2019 9,750 8 View
I have exported the centerline of my vessel and its branches as a matrix in matlab.... Now I want to detect the main vessel and the branches and color them differently ... Any one has an idea?
01 January 2015 5,469 7 View
I have the 3D dimensions of my centerlines. I need to calculate the normal vectors at each point in order to draw the surfaces. Can anyone help me?
01 January 2015 5,447 3 View
I have done aorta simulations in Fluent for three meshes. How can we say which one has the better quality for my further tests? The results are nearly the same.
12 December 2014 5,100 6 View
I need a quick step by step guide to perform static and dynamic simulation for blood flow in an artery in Fluent. I am a total novice with the software and the topic, and the user's guide is...
11 November 2014 1,160 11 View
There are several methods that measure the density, diffusion coefficient and velocity of fluorescently labeled macromolecules in cells, but I can't find a way for microfluidics systems.
10 October 2014 2,137 18 View
When testing a biosensor with different concentrations of antigen, it is said that the electrode should be flushed with PBS. Is PBS alone sufficient or the washing protocol with PBS+Tween 20 and...
04 April 2014 341 0 View
I want to make a pencil lead electrode. I have used different types HB, 2B, 2H but I haven't recorded a good signal in cyclic voltammetry. Does anyone have any experience?
12 December 2013 6,897 30 View
I want to develop a sensor. I am confused because some sources say I have to add a capture antibody and then a detection antibody. While searching the products I can only find anti-marker Ab and...
11 November 2013 2,733 2 View